The Passive Infrared Motion Detector (2GIG‐PIR1‐345) is a wall‐
mounted unit with wide‐angle motion protection. It communicates 
with the 2GIG Control Panel using the 345 MHz frequency. When set 
to High (HI) Sensitivity Mode, the PIR has a maximum range of 30 ft 
deep x 50 ft wide (9.1 m x 15.2 m). The PIR's pet‐immune feature can 
be set to tolerate animals up 55 lbs.
Figure 1 Passive Infrared Motion Detector
Box Contents
Verify that the package includes the following (see Figure 3  PIR and 
Mounting Bracket Detail on page 2):
• 1—Passive Infrared Motion Detector (Part A)
• 1—Plastic Mounting Bracket (Part B)
• 1—Plastic Wall Mount (Part C)
• 1—Plastic Corner Mount (Part D)
• 2—Plastic Wall Anchors With Screws (not pictured)
• 1—Short Phillips Head Screw with Fender (not pictured)
• 1—Short Phillips Head Screw (not pictured)
• 1—Lithium Coin Battery (not pictured)
Inserting and Replacing the Battery
To insert or replace the battery:
Unwrap the PIR and remove the screw from the case bottom.
1
Remove the backplate using a bottom‐to‐top lifting motion.
2
Insert the battery. 
3
Always match the plus (+) sign on the battery with the flat side of 
the compartment and the minus (‐) sign on the battery with the 
spring side.
Replace the PIR cover.
4
WARNING:
Failure to follow these warnings and instructions can 
lead to heat generation, rupture, leakage, explosion, fire, or 
other injury, or damage. Do not insert the battery into the 
compartment in the wrong direction. Always replace the 
battery with the same or equivalent type (see Specifications 
on page 4). Never recharge or disassemble the battery. Never 
place the battery in fire or water. Always keep batteries away 
from small children. If batteries are swallowed, promptly see 
a doctor. 
• Always dispose and/or recycle used batteries in accordance with 
the hazardous waste recovery and recycling regulations for your 
location. Your city, state, or country may also require you to 
comply with additional handling, recycling, and disposal 
requirements. 
Configuring the PIR Features
Ensure that you have inserted the PIR battery as described in Inserting 
and Replacing the Battery. Then configure the features as follows:
Figure 2 PIR Pet Immune and Sensitivity Features
A PET: This is the pet‐immune tolerance setting (33 LBS or 55 LBS).
B TAMPER: This is the tamper switch.
C SENS: This is the sensitivity setting (High or Low).
Step 1: Setting the Pet Immune Feature
To set the pet immune feature to an appropriate weight:
NOTE:
Do not aim the PIR at stairs, furniture, or other surfaces 
that a pet may climb on. The PIR provides immunity when the 
room temperature is above 50° F (10° C) and below 90° F (32° 
C). When mounting the PIR with the plastic mounting bracket, 
for best protection ensure the PIR is mounted to the wall or 
corner with NO tilt (see Lens Pattern and Tilt Angles on 
page 3).
1
With the backplate off, locate the left jumper block immediately 
above the battery compartment. This is the block labeled PET (see 
Figure 2  PIR Pet Immune and Sensitivity Features).
Gently pull out the jumper and slip it over the desired pins to set 
2
one of the pet‐immune tolerance settings:
• 33 LBS. Tolerates pets up to 33 lbs (15 kg).
OR
• 55 LBS (Default). Tolerates pets up to 55 lbs (25 kg). 
3
Continue with the next step below. 
Step 2: Setting the Sensitivity Feature
Locate the right jumper block immediately above the battery 
1
compartment on the right. This is the block labeled SENS (see 
Figure 2  PIR Pet Immune and Sensitivity Features).
Gently pull out the jumper and slip it over the desired pins to set 
2
the desired sensitivity mode:
• LOW (Default). Low sensitivity. This is the recommended 
setting for pets.
OR
• HIGH. High sensitivity. 
Continue with Step 3: Powering ON the PIR on page 2.