Model 7325-106 Multi-Party Amplifier Enclosure
Page

Specifications

Construction/finish .......................................................... Sand-cast A319 aluminum alloy, cam-style latch,
hinged door with gasket; gray enamel paint
Mounting ................................................ Wall, column, or pole (mounting kit required for pole mounting),
four 0.44-inch (11.2 mm) mounting holes
Connections................................................................................ Internal screw-type barrier terminal blocks
External controls ......................................................................................................... Rotary selector switch
Dimensions ................................................... 14.50 H  10.38 W  9.6 D inches (368.3  263.6 244 mm)
Temperature range (operating and storage) ........................................ −22º F to +158º F (−30º C to +70º C)
Shipping weight .................................................................................................................. 20.4 lbs. (9.3 kg)
Approvals
NRTL listed .............................................................................................Class I, Div. 2, Groups A, B, C, D;
Class II, Div. 2, Groups F, G;
Class III, Div. 2
Class I, Zone 2, Group IIC, Class II, Zone 22
when used with listed 701-305, 701-905, 751-005 or 751-905 Amplifier
Enclosure environmental rating: Type 4X and 13
CE Mark

Replacement Parts

Contact GAI-Tronics for replacement part information.