3.2.2) Amplifier Internal Signal

The amplifier can generate sine signal from 1Hz to 15kHz with 1 Hz
increments that the user can adjust with the Sine Frequency Generator
Switch. Connect DC power source and drive signal to shaker power input.
Activated by pulling switch up. Raise or lower the Sine Frequency Generator
Switch to the desired Sine frequency. Adjust the Gain of the amplifier by
turning the Gain Knob clockwise. The frequency of the generated sine signal
will be visible on the LCD Screen.

3.2.3) Amplifier External Signal

Start the external signal source. Activated by pulling switch down. Adjust the
Gain of the amplifier by turning the Gain Knob clockwise.

3.2.4) Amplifier Maintenance and Troubleshooting

The only user replaceable part is the fuse placed inside the amplifier as
shown below. The fuse is 6A.
10