Dynalabs DYN-C-1005-LN Manual do produto - Página 5
Procurar online ou descarregar pdf Manual do produto para Acessórios Dynalabs DYN-C-1005-LN. Dynalabs DYN-C-1005-LN 8 páginas.
All rights reserved. Reproduction or issue to third parties in any form whatsoever is not permitted without written authority from the proprietors.
2.3) Specifications
Table 1: Specifications datasheet
(g)
Full scale
acceceleration
(mV/
Sensitivity
g)
(Hz)
Frequency
range (±5%)
(%)
Non-linearity
(full scale)
(μg/
Noise (in band)
√Hz)
(mg/
Bias
°C)
temperature
(g)
Shock
survivability
Environmental
Table 2: Environmental Specifications datasheet
Protection Level
Operating Voltage
Operating Temperature
Operating Current Consumption mA
Isolation
1002LN
1005LN
±2
±5
1,350
540
700
1,150
0.15
0.15
9
21
±0.2
± 0.5
2,500
2,500
1010LN
1030LN
±10
±30
270
90
2,000
2,300
0.15
0.15
40
100
± 1
± 3
2,500
3,000
-40 °C to +100 °C
Case isolated
1050LN
1100LN
±50
±100
54
27
2,700
2,900
0.15
0.15
180
340
± 5
± 10
3,000
3,000
IP 68
5 V
20 V
–
7 mA
1200LN
±200
13.5
2,500
0.15
680
± 20
3,000
5