Automation Controls Group UniDrive SCC-3 Manual de instalação e resolução de problemas - Página 6

Procurar online ou descarregar pdf Manual de instalação e resolução de problemas para Unidade de controlo Automation Controls Group UniDrive SCC-3. Automation Controls Group UniDrive SCC-3 11 páginas. Smart conveyor control generation iii

Automation Controls Group UniDrive SCC-3 Manual de instalação e resolução de problemas

Feedback LED Indicators

2.5
The control board contains four (4) LED feedback indicators:
One (1)
Red
Fuse LED
One (1)
Red
Fault LED
Amber
One (1)
Motor LED
One (1)
Green
Power LED
To learn more, see 5.1 Feedback LEDs and 5.2 Firmware
Version Display.

Configuration Switches

2.6
The control reads the configuration switches only when the
unit is powering up. To change a setting, disconnect power,
set the switch, and then reconnect power. The OFF position
is to the Left and the ON position is to the Right as seen in
Figure 1: SCC-3 Controller Components. Switch descriptions
are given in the following table:
OFF Setting
Switch: Description:
Counter-Clockwise*
1
Rotation Direction
Mode ZPA/ZIP
ZPA
2
Zone Type
3
Exit/Xport
Target Speed
4
(with SW5, SW6)
Target Speed
5
(with SW4, SW6)
Target Speed
6
(with SW4, SW5)
Motor Selection
100W24
7
Braking & ZMH
Enabled
8

Table 4: Configuration Switch Settings

*NOTE: The direction of rotation is defined when viewed
from the back side of the motor with the shaft extending
away from the viewer.
NOTE: The switches are read during power-up only.
Set the switches, and then connect power to the board.

Upstream Cable Connection

2.7
This connector is intended for use with a 6-wire modular phone
cable to connect to an adjacent upstream SCC board. See Section
5.3 for information on the cable. The cable is not provided.

Downstream Cable Connection

2.8
This connector is intended for use with a 6-wire modular phone
cable to connect to an adjacent downstream SCC board. See
Section 5.3 for information on the cable. The cable is not provided.

Mounting Plate/Heat Sink

2.9
This component is for mounting the control assembly to the
conveyor frame using two ¼ inch or 0.25 in (6.35 mm) bolts to keep
the controller cooler.
ON Setting
Clockwise*
ZIP
Entry/Xport
See Table 6: Operating Speeds.
125W24
Disabled
CAUTION: If mounting the control on a curved section of
conveyor, use washers between the mounting plate and
the conveyor frame. This is to assure that the mounting
plate is not distorted, causing damage to the enclosed
printed circuit board assembly.

Cover

2.10
CAUTION: Removal of the cover will void the warranty.
The cover does not make the controller waterproof or
dustproof.
The cover can help reduce the severity of damage to the
controller from foreign objects.
3

Installation Guide

This section describes how to install and use the SCC-3 and
UniDrive® Motor in the most common configurations. For
additional information, refer to the application notes.
1. Mount the Control
2. Select a Motor
3. Select a Speed
4. Configure the Location
5. Configure the Operating Mode
6. Configure the Rotation
7. Configure Communications
8. Connect User Input/Output
SCC-3 Product 110515 Revision 1.3 April 19, 2018 | Page 6