HID EDGE EVO EH400-K Manual de instalação
Procurar online ou descarregar pdf Manual de instalação para Controlador HID EDGE EVO EH400-K. HID EDGE EVO EH400-K 13 páginas. Standard networked controller
I N STAL L ATI ON G UI DE
EDGE EVO®
Standard Networked Controller
EH400-K/ESH400-K
EDGE EVO is the next evolution in access control hardware solutions. A true IP solution that meets the demands of
open architecture, IP-centric environments, EDGE EVO provides fully distributed intelligence and decision making right
to the door, leveraging the IT infrastructure to the maximum extent possible. Leveraging Power-over-Ethernet (PoE),
EDGE EVO reduces door installation costs by not requiring a separate local power supply under many circumstances.
The Standard Networked Controller is a fully integrated single-door controller offering discrete I/O and Wiegand/
Clock-and-Data interfaces to readers. Additionally, connect native Hi-O™ devices (readers, locks, pushbuttons) and
EDGE EVO Hi-O Modules to the Hi-O bus, providing secure communication around the door. Hi-O involves devices with
built-in intelligence and a CANbus that links all the devices together. Password protect or encrypt Hi-O CANbus data
traffic. Each Hi-O device (such as the push plate, electric strike, card reader and door operator) is connected to the
CANbus by a single, four-wire cable. Two wires supply power and the other two are used for data communication.
Specifications
CONDITIONS
DC Input (NSC)
DC Input (MAX)
Supervised inputs
(AC, Batt, REX, Door Mon) (MAX)
Data 1/CLK , Data 0 / Data (MAX)
GRN LED, RED LED, Beep, Hold (MAX)
External Tamper (MAX)
AUX 12/24 VDC Input
CAN DC
PWR Output
(MAX)
PoE Input
AUX 12 VDC
Reader DC
PWR Output
AUX 24 VDC
(MAX)
PoE Input
AUX 12 VDC
Input
AUX 24 VDC
Strike***/
Input
AUX Relays
NC or NO
DC Output
(MAX)
PoE Input
AUX/PoE
Input
Legend
AUX = Auxillary input or output
CAN = CANbus
NSC = Normal Standby Condition
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
© 2014 - 2017 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID Brick logo, the Chain Design, iCLASS, EDGE EVO, and Hi-O are trademarks or registered
trademarks of HID Global, ASSA ABLOY AB, or its affiliate(s) in the US and other countries and may not be used without permission. All other trademarks, service marks, and product
or service names are trademarks or registered trademarks of their respective owners.
VOLTAGE DC
+12 VDC
+24 VDC
PoE (+48 VDC NOM) 0.085 Amp 4.08 W
+12 VDC
+24 VDC
PoE (+48 VDC NOM)
0-+5VDC Reference
+5VDC (NOM)
+10.8 to +24 VDC
+ 24 VDC (NOM)
+9.8 to +12.25 VDC
+10 to +12 VDC
Unregulated
(Wet) Jumpers
+23 to +24 VDC
Regulated (Wet)
Jumpers - 12 VDC +10 to +12 VDC
Unregulated
+16.5 to +24 VDC
(Wet) Jumpers
Regulated (Wet)
+10 to +12 VDC
Jumpers - 12 VDC
Jumpers Set to
+12 to +24 VDC
Dry
External
PoE = Power over Ethernet
NC = Normally Closed
NO = Normally Open
An ASSA ABLOY Group brand
OPERATING
CURRENT
POWER
TEMPERATURE
0.18 Amp
2.16 W
0.14 Amp
3.36 W
1 8.00 W
1 .50 Amp
36.00 W
0.30 Amp
14.40 W
0.005 Amp
0.025 W
(sink)
N/A
N/ A
0.005 Amp
0.025 W
(sink)
0.02 Amp
0. 1 00 W
1 .2 Amp*
28.80 W
0.4 Amp*
9.60 W
32° - 122°F
(0° - 50° C)
0.32 Amp*
3.92 W
0.60 Amp*
7.35 W
0.58 Amp*
7.11 W
8.40 W
0.70 Amp*
16.80 W
8.40 W
0.36 Amp* 8.64 W
0.58 Amp* 6.96 W
2 .00 Amp ** 48.00 W
* Combined output ratings not to exceed V*I = W:
• 1.2 Amp (+ 24 VDC Aux Input, 28.8 W)
• 1.2 Amp (+ 12 VDC Aux Input, 12.96 W)
** Each relay
*** S hared between each relay
82000-921, Rev. D.3
REGULATORY
CABLE LENGTH
REF NUMBER
Hi-O CANbus
Total Length:
100 ft (30 m)
22 AWG
0.65 mm
0.33 mm
2
Maximum between drops:
30 ft (10 m)
KE400CX
22 AWG
0.65 mm
0.33 mm
2
RJ-45
328 ft (100 m)
Category 5 K
Regulatory Reference
Number Deciphering
X
= K for Black
1
G for Gray
X
= N for non-Solo
2
S for Solo
X
N
1
2