activated with the switch labeled HPF. The middle one is the off position. The
upper position of the switch turns on a high-pass filter with a frequency
of 120Hz with 6dB/oct order. The lower position of the switch turns on a
high-pass filter with a frequency of 60Hz with 6dB/oct order.
Another pillar of the filter section is the filter system
implementing the AIR function. In this case, we mean a
filter operating at the upper limit of the audible range and
at a higher frequency. This creates a very careful
shelving-like boost at the top of the audible frequency
range and complex saturation products at the high
frequency range, which makes it feel very airy and
pleasant. There are two available frequencies assigned to
the AIR function, which you can activate with the Dyn Air switch. The
middle position of the switch is the off state. By turning the switch up,
the 30KHz frequency can be reached. By turning the switch down, the 20KHz
frequency can be selected. If the compressor is switched off, the effect of
OUTPUT ATTENUATOR
At
The Bishop Channel Strip has an output attenuator to
make the most of the sound difference between the
amplification modes and that the built-in optical
compressor can be used most widely. You can
attenuate a total of -12dB from the output level, using
the six-position rotary switch, of which the first option
is the off state. Using the attenuator may reduce the signal/
noise ratio of the device.
Sl
SIDECHAIN LINK
There may be a recording situation where it is necessary to
the AIR function is static. But if the compressor and
the AIR function are switched on at the same time. The AIR
function is implemented dynamically in such a way that
the greater the gain reduction on the compressor,
the boost in the AIR band will be higher.
SC. LINK