1.
Using a 5/32" hex wrench temporarily loosen the
armature bracket assembly screws roughly 1-1/2
turns to allow the upper armature bracket to move
in and out freely (Ref. Figure "A").
2.
Close and latch the door. The mating surfaces of
the lock and armatures should fully contact each
other. If necesssary slide each armature in or out
to ensure full contact is made with the lock while
still allowing the door to properly close and latch.
3.
When the desired adjustment is acheived slowly
open each door, taking care to maintain the
position of the armature. Firmly tighten the
armature bracket assembly screws with a 5/32"
hex wrench, making sure that the locking ribs on
the upper and lower bracket halves properly mesh
(Ref. Figure "A").
3001xTJ31 MANUAL - FORM 3001TJ-001
Bristol, CT 06010
?
Fx/ 860.585.0338
?
ARMATURE ADJUSTMENT
SERIES 3001xTJ31
ELECTROMAGNETIC LOCK
INSTALLATION INSTRUCTIONS
Figure "A"
ASSEMBLY SCREW (TYP.)
ARMATURE BRACKET
ADJUSTMENT RANGE
0"
Page 5
ARMATURE
1"
11/02