Celestron C10-NGT Manual do Protocolo de Comunicação - Página 3
Procurar online ou descarregar pdf Manual do Protocolo de Comunicação para Telescópio Celestron C10-NGT. Celestron C10-NGT 8 páginas. Nexstar hand control
Command Function
Variable rate Azm (or
RA) slew in positive
direction
Variable rate Azm (or
RA) slew in negative
direction
Variable rate Alt (or
Dec) slew in positive
direction
Variable rate Alt (or
Dec) slew in negative
direction
Fixed rate Azm (or RA)
slew in positive
direction
Fixed rate Azm (or RA)
slew in negative
direction
Fixed rate Alt (or DEC)
PC Command
"P" &
chr(3) &
chr(16) &
chr(6) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(3) &
chr(16) &
chr(7) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(3) &
chr(17) &
chr(6) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(3) &
chr(17) &
chr(7) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(2) &
chr(16) &
chr(36) &
chr(rate) &
chr(0) &
chr(0) &
chr(0)
"P" &
chr(2) &
chr(16) &
chr(37) &
chr(rate) &
chr(0) &
chr(0) &
chr(0)
"P" &
Hand Control
Applies to
Response
Versions
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+