4
4mm recess for
Power Transfer
Unit faceplate
1.5mm recess
for the Strike
In-line Power
5
Unit
Power point
existing or an
electrician to
install
Cable from
In-line Power
Unit in door
frame cavity
6
In-line Power
Unit wire
Power Transfer
Unit installed in
door frame
Power Transfer
Unit to In-line
Power Unit
connector
Make sure the
connectors are
pushed together
• Mark and chisel a recess of 4mm for the Power Transfer
Unit faceplate. (So that the Power Transfer Unit faceplate
is flush with frame edge face). Use the Power Transfer Unit
as a template.
• Mark and chisel a recess of 1.5mm for the Strike. (So that
the Strike is flush with frame edge face). Use the Strike
as a template.
• Connect the In-line Power Unit to the Power Point.
• If there isn't a power point available, then a qualified
electrician must be used to install one. The power point
can be located in the ceiling as shown in the diagram
above. Other possible locations for the In-line Power
Unit could include:
– Under the floor
– Behind a panel in the wall.
• Locate the wire from the In-line Power Unit. This will
be in the door frame cavity. Pull the end of the wire out
through the top hole in the door frame.
• Connect the Power Transfer Unit to the wire from the
In-line Power Unit.
• Insert the Power Transfer Unit into the door frame. As you
do this, carefully guide the excess wire back into the door
frame cavity. Fix using 2 black wood screws from KIT D.
NOTE: Do not over tighten these screws. Do not use power tools.
• Insert the strike and fix using 2 wood screws from KIT A.