Dynamco CYCLOPS PARALYSER 485 Instruções para o utilizador - Página 7
Procurar online ou descarregar pdf Instruções para o utilizador para Sistema de segurança Dynamco CYCLOPS PARALYSER 485. Dynamco CYCLOPS PARALYSER 485 13 páginas.
OVER-RIDE cont'
PIN Code
!
If the P485 is triggered, allow siren to reset automatically (after 30 seconds) by sitting inside car
with doors shut. If the siren is switched off, wait for indicators to stop flashing.
!
Turn the ignition switch to the "ON" position; the status LED will glow constantly.
!
Turn ignition switch back to the "ACC" position; the status LED will begin to flash slowly.
!
Switch ignition switch to the "ON" position when the number of flashes match the 1st digit of the
PIN.
!
Repeat previous two steps for the remainder of the PIN.
NB: over-riding the P485 in no way over-rides the vehicle's onboard immobiliser. The factory fitted
immobiliser system is totally separate, refer to manufacturers over-ride instructions.
*** Any digit marked "0" indicates ten flashes.
CHANGING PIN
The emergency over-ride pin can be changed at any time while the P485 is disarmed. To enter a new
"pin", carry out the following procedure: -
!
Disarm system by pressing the unlock button on the remote control or using the existing PIN.
Ensure the bonnet and door driver's door are open throughout the entire procedure.
!
Turn the ignition switch from the ACC position to the "ON" position 19 times; count each time key is in
ON position. Leave the ignition switch in the "ON" position when the 19th count is reached.
!
The red status LED will light up and glow constant.
!
Enter the 1st digit (thousands) by turning the ignition switch back to the "ACC" position then count
the flashes.
!
Turn the ignition switch to the "ON" position when the correct number of flashes is counted for the
new PIN.
!
Repeat the previous two steps for the remaining digits of the new PIN.
When the final digit has been entered the red status LED flashes quickly to confirm a new "PIN" has
been entered.
- Page 7 -