Selection and Specifications

Model
Package Configuration
Power Quality Form Factor
Input Voltage (@ 50/60 Hz)
Output Voltage
Shunt Field Voltage & Current
Output Rating (hp)
Output Current (continuous)
Current Overload Capacity
Current Limit
Transient Protection
I.R. Compensation
Speed Adjustment
Speed Range
Speed Regulation
Maximum Speed
Minimum Speed
Acceleration
Deceleration
Dynamic Braking
Plugging Capability **
Electrical Connections
External Fusing Required
Operating Temperature
Thermal Protection
Mounting Orientation
Corrosive Gases
Weight
Agency Approvals
Replacement Potentiometer
Manual Reverse Switch
* For accessories details, please visit www.AutomationDirect.com.
** Plugging is a method of rapidly changing motor direction by reversing motor armature polarity, while the motor is still running.
*** To meet NEMA4 requirements, GSDA-MREV requires a user provided external exclosure.
IronHorse GSD3 DC Drives User Manual – 1st Ed, Rev C – 10/15/2019
GSD3 Series DC Drives – Selection & Specifications
GSD3-
GSD3-
24A-2CJ
24A-2CL
open frame
12 or 24 VAC ±10%
0–12 or 0–24 VDC
10 VDC @ 12 VAC
10 VDC @ 12 VAC
20 VDC @ 24 VAC
20 VDC @ 24 VAC
(1A max)
1/50 – 1/40 @ 12V
1/50 – 1/25 @ 12V
1/25 – 1/20 @ 24V
1/25 – 1/12 @ 24V
150 mA to 2A (DC)
150 mA to 3A (DC)
adjustable from 40% to 120% of base speed
adjustable from 0% to 30% of maximum speed
Internal fusing is included which is adequate for GSD3-240-3N4 120 VAC line and neutral inputs.
Refer to "Fusing" (page 7) and "Wiring Diagrams" (page 7) for external fusing requirements for
-10 to 45 °C
[14 to 113 °F]
2.9 oz
2.6 oz
[83g]
[75g]
RoHS
Optional Accessories *
GSD3-
GSD3-24A-3N4
240-2CJ
NEMA 4
open frame
1.4
100 VDC @ 120 VAC
200 VDC @ 240 VAC
(0.75A max)
(1A max)
1/50 – 1/6 @ 90V
1/25 – 1/3 @ 180V
150 mA to 2A (DC)
200% for 60s
n/a
Metal Oxide Varistor (MOV)
adjustable – full range
5kΩ potentiometer
25:1
±1% of base speed
0.5s (fixed)
0.5s (fixed)
no
no
spade connector lugs
other wiring configurations.
-10 to 40 °C
-10 to 45 °C
[14 to 104 °F]
[14 to 113 °F]
none
can be mounted in any orientation
NOT compatible with any corrosive gases
2.9 oz
20.3 oz [575g]
[83g]
C
GSDA-5K
GSDA-MREV***
GSD3-
GSD3-240-3N4
240-2CL
NEMA 4
120 or 240 VAC ±10%
0–90 or 0–180 VDC
100 VDC @ 120 VAC
200 VDC @ 240 VAC
(0.75A max)
1/50 – 1/3 @ 90V
1/25 – 2/3 @ 180V
150 mA to 3A (DC)
-10 to 40 °C
[14 to 104 °F]
2.6 oz
20.3 oz [575g]
[75g]
UL
Listed (E333109), RoHS
US
Page 5