AutomationDirect Leadshine EM556S Manual de início rápido - Página 12

Procurar online ou descarregar pdf Manual de início rápido para Accionamentos DC AutomationDirect Leadshine EM556S. AutomationDirect Leadshine EM556S 17 páginas. Stepper drives

AutomationDirect Leadshine EM556S Manual de início rápido
Analog 0–5 V Speed Mode
DM805-AI
Low/High Speed Mode
DM805-AI
External Potentiometer Mode
DM805-AI
Leadshine Stepper Drives Quick Start Guide – First Edition – 11/04/2019
Accel/Ramp
Accel
Decel/LoSpeed
Decel
HiSpeed
Maximum Speed (when Analog
Input = 5V)
COM+
Run/Stop/Pulse
Direction/+Limit
Direction
Speed/(-)Limit
-Limit
Enable/Disable
Disable
Signal GND
+5V Output
0~5V Input
Signal GND
Signal GND
Power GND
+20-80VDC
Motor A+
Motor A-
Motor
Motor B+
Motor B-
Ramp
Accel/Ramp
LoSpeed
DecelLoSpeed
HiSpeed
HiSpeed
COM+
Run/Stop/Pulse
Direction/+Limit
Direction
Speed/(-)Limit
Speed
Enable/Disable
Disable
Signal GND
+5V Output
0~5V Input
Signal GND
Signal GND
Power GND
+20-80VDC
Motor A+
Motor A-
Motor
Motor B+
Motor B-
Accel/Ramp
Accel
Decel/LoSpeed
Decel
HiSpeed
Maximum Speed [when Analog input = 0V
(negative direction) or 5V (positive direction)]
COM+
Run/Stop/Pulse
Direction/+Limit
+Limit
Speed/(-)Limit
-Limit
Enable/Disable
Disable
Signal GND
+5V Output
0~5V Input
10k
Signal GND
Signal GND
Power GND
+20-80VDC
Motor A+
Motor A-
Motor
Motor B+
Motor B-
Leadshine Stepper Drives Quick Start Guide
Run
0~5V
20-80 VDC
Input
Multi-Function Inputs
Run/Stop Inputs
Run
Limits Inputs
20-80 VDC
Enable/Disable Inputs
Run
0-2.5V Negative
2.5-5V Positive
20-80 VDC
Mode Diagram Overview
Description
The active function of each
input is shown next to the
external switches in the Mode
diagrams� Example: In Analog
0-5V Speed Mode, the inputs'
functions are Run, Direction,
-Limit, and Disable�
The Run/Stop function (in
analog modes) uses accel
and decel ramps to transition
speed�
The Limit inputs are direction-
sensitive and are Normally
Open (they allow motion if
left unconnected)� The Limit
function uses decel and accel
ramps� Note that only the
-Limit is available in Analog
0-5V Speed Mode�
This input is often left
unconnected� The Disable
input does not use a decel
ramp (stops quickly), but does
use an accel ramp to restart�
Once the drive is disabled, the
Run input should be removed
before the drive is re-enabled�
Otherwise, the drive may lose
synchronization with the motor
on restart (if accel or set speed
is high)�