Physilog configuration for running measurements

5.2.
The configuration of Physilog®5 can be modified using Research ToolKit software or the
Android application. This allows to optimise the sensor settings for different applications. For
running measurements the configuration must be set as indicated below, otherwise the
software cannot analyse the data. The correct configuration is pre-installed when you order
a PhysiRun Live, so you don't need to modify the configuration of the Physilog®5.
Sensor
Accelerometer
Gyroscope
Barometer

Handling / Maintenance

5.3.
Physilog®5 should be handled carefully. In particular, it should not receive shocks, such as
fall, crushing, being hit etc. Do not press too hard on the on/off button, this can damage the
button.
Warning: Do not use or charge the Physilog® if the sensor or its case is
damaged. Contact Gait Up about what further action is needed when the case
is damaged. In case the battery is damaged immediately move the device away
from flammable materials and contact Gait Up's customer support.
Sensors can be placed on the foot in any orientation, it will not influence running
measurements.
You need to perform running measurements with two sensors (one on each foot) when
using the application.
To benefit from the maximal battery life, fully charge Physilog® sensors before doing
measurements (LED shines green when connected to computer or charger, you can also
check the battery level with the App).
Physilog®5 can be used outside. Do not use Physilog®5 to measure water-sport
activities without additional waterproofing.
Storage: Store in a cool (0°C – 30°C) and dry place. The provided box is the perfect
place for your sensor.
Cleaning: Sensors can be cleaned gently using alcohol wipes. Before you clean the
device make sure it is turned off and disconnect all cables. Alcohol used in excess may
damage the sensor's waterproofing. Make sure to use wipes and not put liquid alcohol
directly on the sensor.
Sensors do not need yearly recalibration.
PhysiRun Live mobile user manual v1.3.1 Date: 02.05.2019
Copyright © 2018-2019, All Rights Reserved - Gait Up SA. CH-1015 Switzerland
Sampling rate
256Hz
256Hz
off
EPFL Innovation Park, Bat C. CH-1015 Lausanne
Sensor range
+/-16 g
+/- 2000 deg/s
-
Gait Up SA
www.gaitup.com
TVA CHE-145.136.760
11