e. Once you have replaced one of the cartridges/membrane with the
faucet (Figure-2) open the ball valve (Figure-5) at the water supply.
Let all of the air out from inside the ultrafiltration system. Once a con-
tinual water flow comes out of the faucet, let it run for 30 seconds
and then close the faucet. If in the beginning, the water runs black,
don't worry, this is normal, it's caused by the residue that the granu-
lated carbon filter lets off. Drain this water. The water will run clear
not long after this. Check for leaks, if there are any, close the valves
and fix them.
Precaution 1: If there is any water leak in any area of the tube connections, re-
move it and cut off 0.5cm. Then reconnect it. If the leak s produced on any thread,
unscrew the piece, apply more Teflon and screw it back on.
6.2. - Procedure for replacing the WATER STOP antileak absorbent
material
In the case of having to change the WATER STOP Antileak absorbent material;
you must do as follows:
d.
Lower the arm on the WATER STOP Antileak system and it's ready for use.
a. Raise the arm on the WATER STOP Antileak system, to cut off the water supply
(if there is a leak the arm will already be raised
b. Throw away the current absorbent material.esechar el material absorbente que
hay colocado.
c. Replace it with a new absorbent material