Specifications

Logic Interfaces:
Access types:
CLK rates supported:
Software Interface:
Testpoints:
Interface:
Dimensions:
Construction:
PCI 32 bit Universal Voltage.
All PCI supported
25-66 [likely work at higher rates as PCI signals are matched and
controlled. ]
Passive, no SW required for adapter
PCI signals plus JTAG and grounds
PMC front bezel directly, rear IO via SCSI connector.
minimized to cover as little of the PMC as possible.
High Temp FR4 Multi-Layer Printed Circuit, Through Hole and
Surface Mount Components.
Embedded Solutions