Hidrotermal HIDRO-SPR100(H) Manual do utilizador - Página 4

Procurar online ou descarregar pdf Manual do utilizador para Bomba para piscina Hidrotermal HIDRO-SPR100(H). Hidrotermal HIDRO-SPR100(H) 6 páginas.

5.Controls Prior to Initial Start-up
Verify that the pump shaft turns freely.
Check that the mains voltage and frequency are according to the name plate.
The hydromassage assembly should be equipped with a system to prevent the pump
from starting up if a minimum water level is not present.
Check the rotating direction of the motor, which should concur with that indicated on
the fan cover.
If the motor does not start up, try to locate the problem in the table of most common
faults and their possible solutions that is provided further on.
THE PUMP SHOULD NEVER OPERATE DRY.
6.Start-up
Start electrically the pump only when the suction and discharge pipes are connected
to the corresponding inlets and outlets. Check that there is no obstacle in the pipes.
Apply voltage to the motor and suitably adjust the jets to obtain the dwsired flow.
7.Maintenance and clean
Our pumps for hydromassage facilities do not require any special maintenance or
programming.
If the pump will be idle for a long period of time, it is recommended to disassemble,
clean and store it in a dry, well-ventilated place. If the supply cord is damaged, it must
be replaced by the manufacturer or its service agent or a similarly qualified person to
a hazard.
Pump can be automotive empty water after correct installation.
When the pump needs to clean (1) filling with water up to level position of bathtub's
nozzle, (2) operating 2-3mimute,(3) exhausting water of bathtub after engine stop.
8.Trouble Shooting Guide
SYMPTOM
PUMP DOES
NO TURN
PUMP NOT
PUMPING
PROPERLY
POSSIBLE CAUSE
NO POWER
TO PUMP
BLOCKAGE OR
LEAK
LOW VOLTAGE
※Incoming power to the pump?
※Is circuit breaker on?
※Is GFCI operating properly?
※Is the air switch plugged in?
※Jets should be pointed away from the
suction inlet so air is not forced into pump
suction.
※Is the in-tub suction inlet blocked or
covered?
※Is there any debris in the pump housing?
※Is there a leak in the piping or the pump?
※Is the proper voltage applied to the pump?
※Is there an extension cord being used?
3