10.Note

Before reading and understanding the manual instruction, please do not operate the device.
※ Forbid installing the device near heat source or take anti-heat protective measures when
install near the heat source. It is also forbidden to connect the device with the hot-water
pipeline or the pipeline with the possibility of hot-water returning. Forbid the product
under the temperature lower than 1 ℃ . Protect resin from freezing which may result in
resin broken and disabled.
※ If the raw water fails to meet the standards of municipal tap water, such as the sediment
concentration or residual chlorine content exceed the stand, etc., the pretreatment device
should be installed before the device.(Such as Y type fliter, ultra filter, and so on.)
※ During the operation, please check the brine tank regularly to ensure that there is brine in
the tank. And when adding brine, please make sure that volume of brine should be 2/3 of
the tank. When it is less than 1/3, please add brine in time. (Attention: make sure the
dissolving salt time is more than 6 hours so as to make the saline solution saturate)
※ Please strictly use the salt of more than 99% purity only. Any salt with additive or large
particles is forbidden to add.
※ Sodium used in the water softening process should be considered as part of your overall
dietary salt intake. Contact doctor if you are on a low sodium diet.
※ Please use this product under the water temperature between 5~45 ℃ , water pressure
0.15~0.6 MPa. Failure to use this product under such conditions voids the warranty.
※ Without use for a long time or the pressure of the inlet water is instable, please close the
inlet port and turn off the power. Before using again, please firstly conduct a regeneration
cycle through manual operation so as to ensure the quality of soften water.
※ If the water demand is increasing (Compared to usual demand) or the hardness of raw
water is rising. please reduce the regeneration cycle and increase the regeneration times,
ensuring the softened water yield.
※ When using the softener for the first time or the device is idle for a long period, it is a
normal that the outlet water is yellow. Please put it into use after 2~3 minutes of rinsing.
※ Sometimes the brine in the brine tank will forms salt bridge. That is, there is a space
under the brine which prevents the salt from being dissolved and hinders the resin
regeneration. It is suggested to check regularly. If there is salt bridge, please mash it.
※ As the product is constantly updating, it is possible that the real product does not
completely conform with the manual instruction. It is subject to the real product.
Special note: The water pressure of tap water is changeable(Normally the pressure in night
time is higher than day time.),so pay attention to each connection to check if there is any
leakage at the first two days after products installed.