Insert the connecting cable into the indoor unit.
C
Don't connect the cable to the indoor unit.
Make a small loop with the cable for easy
connection later.
Tape the drain hose and the connecting cable.
D
• Connecting cable
Indoor unit installation
E
Hang the indoor unit from the hooks at the top of
the installation plate.
Insert the spacer etc. between the indoor unit and
the installation plate and separate the bottom of
the indoor unit from the wall.
Indoor unit
Installation plate
8cm
Connecting the pipings to the indoor unit and
F
the drain hose to drain pipe.
Align the center of the pipings and sufficiently
tighten the flare nut by hand.
Indoor unit tubing
Tighten the flare nut with a wrench.
Torque wrench
Indoor unit tubing
Spacer
Flare nut
Pipings
Spanner (fixed)
Flare nut
Connection pipe
Capacity
(Btu/h)
1/2"[5.5kg . m]
18K, 24K, 26K
5/8"[6.6kg . m]
When extending the drain hose at the indoor unit,
install the drain pipe.
Drain hose
Vinyl tape
Adhesive
Wrap the insulation material around the
G
connecting portion.
Overlap the connection pipe heat insulation and the
indoor unit pipe heat insulation material. Bind them
together with vinyl tape so that there is no gap.
Plastic bands Insulation material
Wrap the area which accommodates the rear
piping housing section with vinyl tape.
Connection
pipe
Vinyl tape
(wide)
Connecting cable
9
Pipe Size[Torque]
GAS
LIQUID
1/4"[1.8kg . m]
3/8"[4.2kg . m]
Indoor unit drain hose
(narrow)
Indoor
unit piping
Wrap with vinyl tape
Pipe
Vinyl tape(narrow)