CONNECTING THE CABLE BETWEEN INDOOR UNIT AND OUTDOOR UNIT

Connect the cable to the
Indoor unit.
Connect the cable to the indoor unit by
connecting the wires to the terminals on the
control board individually according to the
outdoor unit connection.
(Ensure that the color of the wires of the
outdoor unit and the terminal No. are the same
as those of the indoor unit.)
• Cooling model
Terminals on the indoor unit
Color of Wires
Color of Wires
Terminals on the outdoor unit
• Heat pump model
Terminals on the indoor unit
Color of Wires
Color of Wires
Terminals on the outdoor unit
CAUTION
If a power plug is not to be used, provide a circuit breaker between power source and the unit as shown below.
2(N)
1(L)
BROWN BLUE GREEN/YELLOW
BROWN BLUE GREEN/YELLOW
1(L)
2(N)
2(N)
3
4
1(L)
BROWN BLUE
BROWN BLUE
G/Y
G/Y
BLACK
BLACK
RED
RED
BLACK
BROWN
G/Y
RED
BROWN BLUE
BLUE
G/Y
RED
1(L)
2(N)
3
4
Main power source
Air
Conditioner
11
CAUTION
The power cord connected to the indoor unit should
be complied with the following specifications
(Type H05VV-F approved by HAR or SAA).
Capacity
(Btu/h)
The power connecting cable connected to the
indoor and outdoor unit should be complied with the
following specifications
(Type H07RN-F approved by HAR or SAA).
Capacity
(Btu/h)
The connecting cable connected to the indoor and
outdoor unit should be complied with the following
specifications
(Type H07RN-F approved by HAR or SAA).
The length of the power supply cord should be
over 1.8m measured from the power supply cord
entry of the cabinet to the middle of the live pin
of the plug.
Circuit Breaker
Use a circuit
breaker or time
delay fuse.
NORMAL CROSS
-SECTIONAL AREA
18K
1.5mm
2
24K
2.5mm
2
26K
NORMAL CROSS
-SECTIONAL AREA
18K
1.5mm
2
24K
2.5mm
2
26K
NORMAL
CROSS-SECTIONAL
2
AREA 0.75mm