celitron TWE-12100 Manual de operação - Página 4

Procurar online ou descarregar pdf Manual de operação para Sistemas de filtragem de água celitron TWE-12100. celitron TWE-12100 10 páginas. Advanced water purifier system

Function of main parts
Transformer
Low pressure switch
Solenoid valve
RO pump
High pressure switch
Auto flush valve
RO manual version 1.0
Sting 11 B
24VAC is transformed into 24VAC.
Supply power to RO pump, solenoid valve, and auto flus-
hing.
Auto power cut-off when water supply stops.
ON at over 5psi OFF t below 5psi.
After machine stop, water supply is cut off and no waste-
water is drained in order to save water.
Push the water to pressure of 70-100psi.
When the water reservoir is filled with water, it cuts off
power and stops the pump.
Automatically control the flushing cycle, when the system
is started it first flushes for 15 seconds ON, and then
begin increasing pressure to make water for 30 minutes
OFF, and flush again for 15 seconds. It is ON and OFF
until power cut off by High-pressure switch.
CELITRON MEDICAL TECHNOLOGIES KFT
Copyright (C)