4. Description of indicators and control elements
1
Antenna
2
Firing output
3
LED indicator 'Operation'
4
Sensor field 'On'
5
Battery compartment
6
LED indicator 'Battery'
7
LED indicator 'Range Test'
8
LED indicator 'Programming
Mode'
9
LED bar indicator
10
LED 'Output'
11
Sockets for firing output
5. Compatibility
The device can be controlled with these transmitters:
PFC Advanced, firmware V2.6BX or later
It is required that radio channel 41 (434.075 MHz) has been selected. The user can choose this
channel in the menu 'Radio Channel Management'. The device is only able to receive commands and
due to that remote data requests are not possible.
PFS Profi, firmware V2.0d or later
It is required that the device is operated on radio channel 41 (434.075 MHz). The radio channel can
only be determined by the manufacturer.
9
Insert quick-fastening clamps here
Flashes in blue color while the device is in operation
To control the device with the magnetic pen
The battery compartment is on the bottom side of the receiver.
Move the small slider to open and close it.
Flashes in red color as a warning that the battery level is low. Is
continuously lit in red color when the battery level is being
displayed on the LED.
Is lit in green color when the result of the range test is being
displayed on the LED bar.
Is lit in yellow color when a programming mode is active.
There are two different programming modes: Teach in to the
system ID of the transmitter and programming of the firing
channel.
Five green LEDs display the result of the range test and the
battery level. The more LEDs the higher the result.
This bicoloured LED displays the status of the firing output:
1. The flashing in green color is the continuity test.
On for a long period = no continuity
On for a short period (short flashes) = firing line has continuity
2. The LED is lit in red color when firing.
Quick-fastening clamps or banana plugs are to be inserted here.