Setting the fence square with the table

1. Make sure that the electrical plug is removed from the
power point.
2. Push the saw arm (4) down to its lowest position and
engage the release knob (6) to hold the saw arm in the
transport position.
3. Loosen the miter lock (24).
4. Rotate the table (20) until the pointer is positioned at 0º.
5. Tighten the miter lock (24).
7. Using the 6mm hex key provided, loosen the four screws
securing the fence (18) to the base (Fig. a).
a
8. Place a square against the fence (18) and alongside the
blade (Fig. b).
9. Adjust the fence (18) until it is square with the blade.
10. Tighten the screws securing the fence (18).
11. Loosen the Phillips head
screw holding the pointer
of the miter scale (21)
and adjust it so that it
accurately indicates the
zero position on the miter
scale (Fig. c).
12. Retighten the screw
securing the miter
scale pointer.
13. Replace the top section of the fence and secure the
hex screw using the 6mm hex key.
b
c

Changing a blade

DANGER!
Never try to use a blade larger than the stated
capacity of the saw. It might come into contact with the
blade guards. Never use a blade that is too thick to allow the
outer blade washer to engage with the flats on the spindle.
It will prevent the blade screw from properly securing the
blade on the spindle. Do not use the saw to cut metal or
masonry. Ensure that any spacers and spindle rings that
may be required suit the spindle and the blade fitted.
1. Make sure that the electrical plug is removed from the
power point.
2. Push down on the operating
handle (6) and pull the
release knob (5) to
disengage the saw arm (4).
The release knob (5) can be
turned so that it is held in the
retracted position (Fig. d).
3. Raise the saw arm (4) to
its highest position.
4. Using a Phillips head
screwdriver loosen and
remove the screw that
secures the guard retraction
arm (12) to the rotating
blade guard
(Fig. e).
5. Using a Phillips head
screwdriver loosen and
remove the screw that
secures the blade bolt
cover (13) (Fig. f).
6. Pull the rotating blade
guard (11) down then
swing it up together with
the blade bolt cover (13).
When the rotating blade
guard (11) is positioned
14
d
e
f