Autonics FX6Y-I2 Manual de instruções - Página 3

Procurar online ou descarregar pdf Manual de instruções para Instrumentos de medição Autonics FX6Y-I2. Autonics FX6Y-I2 6 páginas. Din w72xh36mm of counter/timer with indication only

Autonics FX6Y-I2 Manual de instruções
Input Connections
Voltage input (PNP)
● Solid-state input (standard sensor: PNP output type sensor)
Sensor
Counter/Timer
Brown
Black
10.8kΩ
Blue
(PNP output)
※ CP1, CP2 (INHIBIT), RESET input part
No-voltage input (NPN)
● Solid-state input (standard sensor: NPN output type sensor)
Sensor
Counter/Timer
Brown
5.4kΩ
Black
Blue
(NPN output)
※ CP1, CP2 (INHIBIT), RESET input part
Counting & Time Operation
Counting operation
● Input mode: Up
RESET
+Max. display value
0
● Input mode: Up/Down-A, B, C
RESET
+Max. display value
0
-Max. display value
Time operation
● Up mode
RESET
INHIBIT
+Max. display value
0
Sensor
Brown
+12V
Black
Inner circuit
Blue
0V
(PNP open collector output)
Sensor
Brown
+12V
Black
Inner circuit
Blue
0V
(NPN open collector output)
Up/Down Counter/Timer
● Contact input
Counter/Timer
+12V
Inner circuit
10.8kΩ
0V
※ Counting speed
Counter/Timer
+12V
5.4kΩ
Inner circuit
0V
※ Counting speed
● Input mode: Down
RESET
+Max. display value
0
-Max. display value
● Input mode: Up/Down-D, E, F
RESET
+Max. display value
0
-Max. display value
● Down mode
RESET
INHIBIT
+Max. display value
0
-Max. display value
Counter/Timer
+12V
Inner circuit
10.8kΩ
0V
: Set as 1 or 30cps
● Contact input
Counter/Timer
+12V
5.4kΩ
Inner circuit
0V
: Set as 1 or 30cps
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
M-69