ZonePro 640/641 Application Guide
Notes - Health Club Application
1. The ZonePro 640 units are located near the front desk area.
2. ZCs in the weight room ands the aerobics room allow source selection and volume
control.
3. The aerobics instructor's microphone is routed only to the aerobics area as the Priority
source and is simply mixed in as the priority source rather than Ducking the primary
source.
4. The Input Link Buss is used to send the inputs down to the second ZonePro device.
5. The TV feed comes from the treadmill room and it is the priority source for that area
overriding the primary source. Whenever the TV is on its audio is routed to the treadmill
room and it can also be selected in the weight room.
6. The locker rooms always have as their primary source the Satellite Music and receive
paging from the front desk.
7. Since we do not need the Aerobics Mic to be routed to any of the zones other than the
aerobics room and we are using the Input Link Buss to duplicate the inputs from the first
ZonePro device to the second, we could include another CD player and route it to the
second mic/line input on the second ZonePro device. The ZonePro devices offer a "Local
Page" facility on each of the mic/line inputs allowing selection between the sources
coming in on the Buss and the local source. This would allow all the zones that are being
fed by the second ZonePro device to have an additional CD source to select from.