Connections
Color
Function
Brown
+V
Blue
0 V
Black
OUT 1
White
OUT 2
Orange
Option input / output
■ NPN open collector output
Brown
LOAD
Black
LOAD
OCP
White
OCP
①
②
Orange
Output
impedance
Blue
• ①: Option voltage / current output model, ②: Option external input model
• OCP (over current protection circuit)
• There is no short circuit protection circuit. Do not connect directly to power or capacitive loads.
• The control output is abnormal when the control output circuit is shorted or over current is
supplied.
• Pay attention to the input impedance of the connected device when using analog voltage
output. Be sure to the voltage drop due to the resistance of the wiring when extending the
wiring.
Installation
■ One-touch fitting
Pneumatic type
Fluid type
12 mm
spanner
17 mm
spanner
■ Bracket
Use spring washers and hexagon wrench bolts (tightening torque: ≤ 3 N m) to select
and install a bracket suitable for your environment.
Connector type
• Bracket A
• Bracket B
■ Installation configuration
• Sold separately: Front cover (PSO-P01), Panel
bracket (PSO-B02/B03)
• Panel thickness: 0.8 to 3.5 mm
Front cover
(PSO-P01)
Panel bracket
(PSO-B02)
Installation
panel
Pressure sensor
Error
Display Cause
When external pressure is input while
adjusting zero point.
ERR1
When overload is applied on control output
ERR2
When 'ST1', 'ST2' setting range is not met in
auto sensitivity setting mode.
ERR3
When applied pressure exceeds high-limit of
display pressure range.
HHHH
When applied pressure exceeds low-limit of
display pressure range.
LLLL
-HH-
Auto shift correction error.
-LL-
-HL-
■ PNP open collector output
Brown
OCP
Black
LOAD
OCP
White
LOAD
①
②
Orange
Output
impedance
Blue
Connect the metal part with a
spanner so that no large force is
applied to the unit body.
(tightening torque: ≤ 10 N m, it may
cause malfunction.)
Cable type
• Bracket C
■ Wiring
• Do not pull the wiring with a force
of more than 30 N.
Troubleshooting
Try again after removing external
pressure.
Remove overload.
Check setting conditions and set
proper setting values.
Apply pressure within display pressure
range.
Set the corrected setting value within
setting pressure range.
Specifications
PSAN-
PSAN-
Model
□V01C□□-□
□01C□□-□
Pneumatic type model: Gauge pressure
Pressure Type
Fluid type model: Gauge pressure
Pressure
Negative
Static
Min display unit
0.1 kPa
0.1 kPa
Rated pressure
0.0 to -101.3
0.0 to 100.0
range
kPa
kPa
Display & setting
5.0 to -101.3
-5.0 to 110.0
pressure range
kPa
kPa
Display type
7 Segment LED, 4 ½ digit
Display accuracy
-10 to 0 ℃: ≤ ±1% F.S., 0 to 50 ℃: ≤ ±0.5% F.S.
Rated pressure
Rated
Max. pressure
×2
pressure ×2
01) Only for static pressure, rated prssure range 100.0 kPa model
02) The unit is sealed structure. It is based on atmospheric pressure 101.3 kPa.
Applicable
Pneumatic type
medium
(air, non-corrosive gas)
Connection type
Connector type
Cable
Ø 4 mm, 5-core, 2 m
Wire spec.
AWG24 (0.08 mm, 40-core), insulator diameter: Ø 1 mm
Front case: PC
Back case: (back port) PC / (bottom
Material
port) PBT+GF15%
Pressure port: Brass-nickel plated
Protection
Connector type: IP40 (IEC standard)
structure
Approval
ᜢ ᜫ
Unit weight
Back port: ≈ 80 g (≈ 165 g)
(packaged)
Bottom port: ≈ 85 g (≈ 170 g)
12 - 24 VDCᜡ (ripple P-P: ≤ 10%)
Power supply
Allowable voltage
90 to 110% of rated voltage
range
Current consumption
≤ 50 mA
01)
Control output
NPN open collector output / PNP open collector output model
Load voltage
≤ 30 VDCᜡ
Load current
≤ 100 mA
Residual voltage
NPN: ≤ 1 VDCᜡ, PNP: ≤ 2 VDCᜡ
Hysteresis
According to output operation mode
Repeat error
±0.2% F.S. ±min display interval
Response time
2.5, 5, 100, 500, 1000 ms
Protection circuit
Output short over-current protection circuit
Insulation resistance
≥ 50 MΩ (500 VDCᜡ megger)
Dielectric strength
1,000 VACᜠ 50 / 60 Hz for 1 min
1.5 mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y,
Vibration
Z direction for 2 hours
Ambient temperature
-10 to 50 ℃, Storage: -20 to 60 ℃ (no freezing or condensation)
Ambient humidity
30 to 80%RH, Storage: 30 to 80%RH (no freezing or condensation)
01) Current output: ≤ 75 mA
02) Refer to 'Output operation mode'. ±1digit error may occur due to pressure unit operation.
Analog output
Voltage (1 - 5 VDCᜡ ±2% F.S)
Output impedance
1 kΩ
Linearity
≤ ±1% F.S
Zero-point
≤ 1 VDCᜡ ±2% F.S.
Span
≤ 4 VDCᜡ ±2% F.S.
Resolution
1/1000 or 1/2000 (different by pressure type and display unit)
Response time
50 ms
Minimum Display Interval
Pressure
Negative
Static
Min display
0.1 kPa
0.1 kPa
interval
1/1000
1/2000
1/1000
Resolution
Display unit
MPa
-
-
0.001
kPa
0.1
-
0.1
kgf/cm
0.001
-
0.001
2
bar
0.001
-
0.001
psi
-
0.01
-
mmHg
-
0.4
inHg
-
0.02
mmH
O
0.1
-
01)
2
01) Multiply display value by 100.
PSAN-
PSAN-□1□□□-□
□C01□□□-□
or sealed gauge pressure
01)
02)
Compound
1 kPa
0.1 kPa
-101.3 to 100.0
0 to 1,000 kPa
kPa
-101.3 to 110.0
-101.3 to 1,100 kPa
kPa
• Pneumatic type:
Rated pressure ×1.5
Rated pressure
• Fluid type: Rated
×2
pressure ×2
Fluid type (non-corrosive gas and
fluid that do not corrode stainless
steel 316L)
Cable type / connector type
Connector type: Ø 4 mm, 5-core, 2 m
Cable type: Ø 4 mm, 5-core, 3 m
Front case: PC
Back case: PA6
Pressure port: SUS304/SUS316L
Connector type: IP40 (IEC standard)
Cable type: IP65 (IEC standard)
Connector type: ≈ 88 g (≈ 173 g)
Cable type: ≈ 90 g (≈ 167 g)
02)
Current (DC 4 - 20mA ±2% F.S)
-
≤ ±1% F.S
≤ DC 4 mA ±2% F.S.
≤ DC 16 mA ±2% F.S.
70 ms
Compound
1 kPa
0.1 kPa
1/2000
1/1000
1/2000
1/1000
-
0.001
-
-
-
1
-
-
-
0.01
-
-
-
0.01
-
-
0.01
-
0.1
-
-
-
-
1/2000
-
0.1
0.001
0.001
0.02
0.8
0.03
0.1