APPLICATIONS ...
"POT" REPLACEMENT
RUN/STOP
MAXj. Speed 3
SIG B
~'Ef~=========~
COM
l"'I\,;j""l----------~~~O
SPO
5
PPR PANEL ENCODER
LINE
FUNCTION
7
FULL SCALE SPEED
I SPO
PGM
. F.S.
9
FULL SCALE FREQ.
IPGM
,F.S.
ENe
11
ADJUST MODE
12
ADJUST RATE
1350
SIGA
1800
1
9000
1
Rd.
Wi
+12 VDC
DRIVE
ANALOG OUTPUT
The Full Scale Speed is the highest running speed desired.
For this application, the maximum motor speed is 1800
RPM.
The Full Scale Frequency is determined by the maximum
motor RPM, the encoder resolution, and the motor to
encoder gearing (if any). In this example, it is
1800 rpm.;. 60 sec/minute x 300 ppr
=
9 kHz
The Adjust input is a panel mounted quadrature encoder
"pot".
The "pot" Adjust Rate (resolution) is 10 RPM for each
quadrature edge (X4 logic). With a 5 ppr encoder, one turn
changes the Speed Setpoint by (5 ppr x 4 x 10 RPM
= )
200
RPM.
~.:.....,;,,---------------------------------
ROTARY TEST STAND
RUN/STOP
~
SPO
6025
SET
INCREASE
~
DECREASE
~
~lElj)lj)lj)lj)
1Ql
LINE
FUNCTION
7
FULL SCALE SPEED
9
FULL SCALE FREQ.
11
ADJUST MODE
12
ADJUST RATE
I SPO
PGM
F.S.
PGM
SIGA
F.S.
ENe
~
12001
12000
Rd.
991
MAXj. Speed
3
;12 VDC
ANALOG OUTPUT
DRIVE
7200
RPM
MOTOR
The Full Scale Speed is the highest running speed desired.
For this application, the maximum motor speed is 7200
RPM.
The Full Scale Frequency is determined by the maximum
motor RPM, the encoder resolution, and the motor to
encoder gearing (if any). In this example, it is
7200 rpm.;. 60 sec/minute x 100 ppr
=
12 kHz
The Adjust input is a pair of remote contacts; one each for
Increase and Decrease Speed functions.
The "mop" Adjust Rate is 99 RPM/sec while either switch is
closed. Note that the Run/Stop input is jumpered; starting
and stopping can be performed with the Run/Pgm key
(provided the PGM DIS switch is Off).