Autonics CTM Series Manual do produto - Página 5
Procurar online ou descarregar pdf Manual do produto para Temporizador Autonics CTM Series. Autonics CTM Series 11 páginas. Programmable digital counters / timers
Também para Autonics CTM Series: Manual (4 páginas)
■ Parameter 1 group (timer)
Parameter
Mark
Counter /
T1-1
timer
01)
C-T
T1-2
Time range
SEC • Refer to the table below.
01)
UP / DOWN
T1-3
mode
01)
U-D
Indication
T1-4
mode
01)
DSpM
Memorize
T1-5
counting
value
DATA
Output
T1-6
operation
mode
OUtM
01)
OUT2
T1-7
output
OUT2
time
01)
OUT1
T1-8
output
OUT1
time
01)
OUT
T1-9
output
OUtT
time
01)
T1-10 Input logic
SIG
Input
T1-11
signal
InT
time
T1-12 Key lock
LOCK
01) When the setting value of the parameter is changed, all outputs are OFF and reset the current value when
returning to the RUN mode
02) [6-digit model] setting range
Counting value
SEC (defaults)
display part
Setting
999.999
display part
0.001s to
Range
999.999s
Counting value
M S
display part
Setting
999959
display part
1s to
Range
9999m59s
[4-digit model] setting range
Counting value
SEC
display part
(defaults)
Setting
9.999
display part
0.001s to
Range
9.999s
03) Appears for 2-stage preset model only
04) In case of T1-6 Output operation mode: FLK.1, FLK.2, INTG, or T1-6 Output operation mode of 1-stage preset
model: OND, OND.1, OND.2, T1-8 OUT1 output time is not displayed, T1-7 OUT2 output time is displayed as
OUT.T.
■ Parameter 2 group (communication)
• Only for RS485 communication model.
Parameter
Mark
Comm.
2-1
address
ADDR
Comm.
2-2
speed
BPS
2-3
Parity bit
PRTY
2-4
Stop bit
STP
Response
2-5
waiting time
RSwT
2-6
Comm. write COmW
Output Operation Mode
For the detailed timing chart for operation output mode, refer to the manual.
Find Quality Products Online at:
Defaults
Setting range
COUN COUN: counter, TIME: timer
02)
UP: 0 → setting time
DN: setting time → 0
UP
[Indicator model]
TOTAL, HOLD, ONT.D: On time display
• HOLD, ONT.D
TOTAL
: You can set the PRESET value.
[Indicator model]
CLR: Resets counting value when
power is off.
REC: Memorizes counting value at the
CLR
moment of power off.
(memory retention)
OND, OND.1, OND.2, FLK, FLK.1, FLK.2,
INT, INT.1, INT.2
, OFD, NFD, NFD.1,
03)
OND
INTG
[2-stage preset setting model]
0.01 to 99.99 sec, Hold
• When 10
digit is flashing, press [◀]
1
HOLD
key once and Hold appears.
[2-stage preset setting model]
0.01 to 99.99 sec, Hold
• When 10
digit is flashing, press [◀]
1
0)10
key once and Hold appears.
[1-stage preset setting model]
0.01 to 99.99 sec, Hold
• When 10
digit is flashing, press [◀]
1
HOLD
key once and Hold appears.
NPN, PNP
• Set the same as settings of input logic
NPN
selection switch.
1, 20 ms
• CTS / CTY
: min. signal width of INA, INH, RESET
signal
20
• CTM
: min. signal width of INA, RESET,
INHIBIT, BATCH RESET signal
L.OFF: Unlock key LOCK,
key LOCK indicator OFF
LOC.1: Locks [RST] key,
key LOCK indicator ON
LOC.2: Locks [◀], [▼], [▲] key,
lOFF
key LOCK indicator ON
LOC.3: Locks [RST], [◀], [▼], [▲] key,
key LOCK indicator ON
SEC
SEC
SEC
M S
9999.99
99999.9
999999
9959.99
0.01s to
0.1s to
1s to
0.01s to
9999.99s
99999.9s
999999s
99m59.99s
MIN
MIN
H M S
H M
99999.9
999999
995959
999959
0.1m to
1m to
1m to
1m to
99999.9m
999999m
99h59m59s
9999h59m
SEC
SEC
SEC
M S
MIN
MIN
99.99
999.9
9999
9959
999.9
9999
0.01s
0.1s to
1s to
1s to
0.1m to
1m to
to
999.9s
9999s
99m59s
999.9m
9999m
99.99s
Defaults Setting range
Display condition
1 to 127
• Do not set the same address
-
001
during multi-comm.
24: 2,400, 48: 4,800, 96: 9,600,
-
192: 19,200, 384: 38,400 bps
96
NONE NONE, EVEN, ODD
-
2 1, 2 bit
-
16 to 99 ms
2-2 Comm. speed: 24
8 to 99 ms
2-2 Comm. speed: 48
2-2 Comm. speed: 96,
20
5 to 99 ms
192, 384
ENA ENA: enable, DISA: disable
-
GlobalTestSupply
www.
Input Connections
• Input: INA, INB / INH, RESET, INHIBIT, BATCH RESET
Display
condition
• Max. counting speed in the contact input: 1 or 30 cps setting (counter)
■ No-voltage (NPN) input
-
-
• Solid-state input
-
Sensor
(NPN output)
Brown
-
Black
-
Blue
• Contact input
Counter / Timer
-
+12 V
5.4 kΩ
Internal circuit
of input part
T1-6
0 V
output
operation
■ Voltage (PNP) input
mode
04)
• Solid-state input
Sensor
(PNP output)
Brown
-
Black
-
Blue
• Contact input
Counter / Timer
+12 V
-
Internal circuit
of input part
5.4 kΩ
0 V
Output Connections
M S
• Solid-state output
99959.9
Counter / Timer
0.1s to
999m59.9s
LOAD
HOUR
99999.9
0.1h to
A:
When using inductive load (relay etc.), surge absorber (diode, varistor etc.) must be connected
99999.9h
between both sides of the load.
• Contact output
H M
HOUR
Counter / Timer
9959
9999
1m to
1h to
99h59m
9999h
LOAD
Sensor
Counter / Timer
(NPN open collector output)
Brown
+12 V
5.4 kΩ
Internal circuit
Black
of input part
Blue
0 V
Sensor
Counter / Timer
(PNP open collector output)
Brown
+12 V
Black
Internal circuit
of input part
5.4 kΩ
Blue
0 V
A
(+)
Power
for load
(DC)
(-)
(Power of load)
.com
Counter / Timer
+12 V
5.4 kΩ
Internal circuit
of input part
0 V
Counter / Timer
+12 V
Internal circuit
of input part
5.4 kΩ
0 V