Autonics LE4SA Instrução - Página 14
Procurar online ou descarregar pdf Instrução para Temporizador Autonics LE4SA. Autonics LE4SA 18 páginas. Din w48xh48mm digital backlight lcd timer
Também para Autonics LE4SA: Manual (17 páginas)
LE4SA Output operation mode
Mode
Time chart
[
OND
]
OND
Time limit contact
Instantaneous contact
UP
ON Delay
DOWN
1. Timing operation starts when power is ON.
2. Time limit output will be ON when timing operation is progressed up to the setting time. Display value will be
HOLD.
3. If selecting time limit 1c + instantaneous 1c mode, instantaneous output will be ON when power is ON and goes
OFF when power is OFF.
4. If pressing RESET key, display value and time limit output will be reset.
[
ONd2
]
ONDⅡ
Time limit contact
Instantaneous contact
UP
ON Delay 2
DOWN
(One-shot output)
1. Timing operation starts when power is ON.
2. Time limit output will be ON during Tout setting time and goes OFF when timing operation is progressed up to
the setting time. Display value will be HOLD.
3. If selecting time limit 1c + instantaneous 1c mode, instantaneous output will be ON when power is ON and goes
OFF when power is OFF.
4. If pressing RESET key, display value and time limit output will be reset.
5. Tout setting range: 0.01 sec to 99.99 sec.
[
FLK
]
FK
Time limit contact
Instantaneous contact
UP
Flicker
(Toff operation
DOWN
precedes)
1. Control output will be repeatedly OFF during Toff setting time and will be ON during Ton setting time when
power is ON.
Ton, Toff > Ta
2. If selecting time limit 1c + instantaneous 1c mode, instantaneous output will be ON when power is ON and goes
OFF when power is OFF.
3. If pressing RESET key, display value and time limit output will be reset.
4. It is able to set each Toff time and Ton time separately. In [
[
FLk1
]
FKⅠ
Time limit contact
Instantaneous contact
UP
Flicker 1
(Ton operation
DOWN
precedes)
1. Control output will be repeatedly ON during Ton setting time and will be OFF during Toff setting time when
power is ON.
2. If selecting time limit 1c + instantaneous 1c mode, instantaneous output will be ON when power is ON and goes
OFF when power is OFF.
3. If pressing RESET key, display value and time limit output will be reset.
4. It is able to set each Ton time and Toff time separately. In [
※ Initial status : UP mode-display value is "0", output is "OFF". DOWN mode-display value is "setting time", output is "OFF".
※ Instantaneous contact(OUT2) will be returned when power is off.
※ RESET key is locked for default set and release the lock to use.
T
POWER
※ RESET
(⑧-⑥)
(①-③)
Set time
0
Set time
0
T
POWER
※ RESET
(⑧-⑥)
(①-③)
Set time
0
Set time
0
Toff
Ton
Toff
Ton
POWER
※ RESET
(⑧-⑥)
(①-③)
Toff
Ton
0
Toff
Ton
0
Ton
Toff
Ton
Toff
Ton
POWER
※ RESET
(⑧-⑥)
(①-③)
Toff
Ton
0
Toff
Ton
0
LCD Timer(Touch Type)
Rt
T
T
Rt
T
T
Toff
Ta
Rt
Toff
Ton
Toff
] mode, timing operation starts with Toff.
Ta
Rt
Ton
Toff
Ton
] mode, timing operation starts with Ton.
T = Setting time, T > Ta, Rt = Reset time
Operation
POWER
T
Time limit
contact
output
T = set time
POWER
T
Time limit
contact
output
Tout = output time
T = set time
Ton
POWER
Toff
Ton
Time limit
contact
output
Ton, Toff = set time
Enables to set Ton and
Toff time differently.
Toff
POWER
Ton
Toff
Time limit
contact
output
Ton, Toff = set time
Enables to set Ton and
Toff time differently.
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
Tout
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
Toff
Ton
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
Ton
Toff
panel
(S)
Field
network
device
(T)
Software
(U)
Other
K-33