PSXX-AR & PSXX-ARSC Manual
CV49 Current Limit/Trip Current value
Default Trip Rate = 1.8 amps
If CV49=0, then the Current Limit/Trip Current jumpers on J6 are enabled. Remember to use either the Jumpers or
the CV settings, NOT BOTH!
Setting CV49 to a value from 1-10 will set the trip rate matching the value.
For example:
CV49=1 Trip Rate = 0.9 amperes
CV49=2 Trip Rate = 1.8 amperes [default]
CV49=3 Trip Rate = 2.7 amperes
CV49=4 Trip Rate = 3.6 amperes
CV49=5 Trip Rate = 4.5 amperes
CV49=6 Trip Rate = 5.4 amperes
Low Current System Trip Current Settings:
For the Digitrax Zephyr [DCS50, DCS51, DCS52], setting values of CV49=01, 02, & 03 is OK.
The NCE Power Cab should use the default value of CV49=02.
For the Power Cab CV49=1 is ok too.
Most 5 amp boosters should be happy with CV49 = 0-5
Audible Short Indication
with an audible short indicating device. It is designed for use with part no. ttxsonalert. The device is
installed with the [+] terminal in the square hole.
You can obtain these components for all PSXX devices from
Tony's Train Exchange: 800.978.3472 [email protected]
Part no. ttxsonalert
Audio Alert
The two holes inside the circle [U8] on the top of the board are for use
Part no. screwtermkitpsxx1
Screw Terminal Kit for PSXX
Rev: A Software Rev: A
Reset Push Button Switch
4