WARNING:
All fire pits are designed and intended for outdoor use only.
WARNING:
For electronic ignition models there must be an electrical shut off ( wall switch or breaker ) on the exte-
rior of the fire pit or on adjacent wall to allow for emergency shutdown and maintenance.
WARNING:
All fire pits must have a gas shutoff on the outside of the exterior of the fire pit to allow for emergency
shut off and maintenance.
WARNING:
Select a location where the fire pit can be attended during operation. Never leave an operating fire pit
unattended or by someone not familiar with its operation or emergency shut off locations.
WARNING:
Both children and adults should be alerted to the hazards of high surface temperatures and should stay
away to avoid burns and clothing ignition.
WARNING:
Young children should be carefully supervised when they are in the area of fire pit.
WARNING:
Clothing or other flammable materials should not be placed on or near fire pit.
WARNING:
Fire pits create very high temperatures - Combustibles must be located far enough away that there is no
risk of ignition.
WARNING:
Overhead Clearance applies to tree limbs and branches only- DO NOT install unit under overhang or
ceiling.
IMPORTANT
:
It is recommended that material such as granite, marble or other dense stone be kept away from
heat and especially flame due to risk of cracking. Manufacturer is not responsible for damage.
• The gas line should be a minimum of 3/4" or larger based on fire pit size and distance from fuel source.
• Select a location with good drainage.
• Choose a location that allows easy access for installation and maintenance of the fire pit.
• Pick a location that allows sufficient horizontal room to enjoy the fire pit while allowing a safe distance from the
heat and flame.
DCI LLC All Rights Reserved: For technical support call 951-805-0314
Selecting the Location
Fire Pit Clearances
Under Valve Box When Applicable 6"
Sides Surrounding Fire Pit 48"
Overhead Clearance 120"
3