Galil DMC-3xx10 Manual de instalação - Página 11

Procurar online ou descarregar pdf Manual de instalação para Amplificador Galil DMC-3xx10. Galil DMC-3xx10 17 páginas. Dmc-3xx1 series integrated amplifier

J4 - Encoder 15 pin HD D-Sub Connector (Female)
Communication with Galil Software
To communicate with the controller, the GalilTools communications software must first be installed.
A free version of GalilTools (GalilTools-Lite) may also be used. These software applications can be
found on the software installation CD shipped with the controller, or online at:
http://www.galilmc.com/support/software-downloads.php
Installation instructions for your operating system can be found in the GalilTools user manual.
http://www.galilmc.com/support/manuals/galiltools/introduction.html
Once the software has been installed, run GalilTools, or GalilTools-Lite and choose your controller.
RS-232 connection
If you are using over a serial connection, the standard baud rate of the DMC-3xx1x motion controller
is 115200. For a standard serial connection over COM1, choose COM1 115200 in the connections
dialog window.

Ethernet connection

If you are connected to the controller via an Ethernet connection, and your network is DHCP enabled,
then the controller will automatically have an IP addressed assigned to it. If your network is not
DHCP enabled, or the connection is only between the PC and the controller, then the controller be
found with the software as no IP address assigned. The GalilTools software will allow you to assign
the controller with an IP address. See the GalilTools documentation for detailed information on using
the software to assign the controller IP address.
Pin #
Label
Description
1
MI+
I+ Index Pulse Input
2
MB+
B+ Main Encoder Input
3
MA+
A+ Main Encoder Input
4
AB+
B+ Aux Encoder Input
5
GND
Digital Ground
6
MI-
I- Index Pulse Input
7
MB-
B- Main Encoder Input
8
MA-
A- Main Encoder Input
9
AA-
A- Aux Encoder Input
10
HALA
A Channel Hall Sensor
11
AA+
A+ Aux Encoder Input
12
AB-
B- Aux Encoder Input
13
HALB
B Channel Hall Sensor
14
HALC
C Channel Hall Sensor
15
+5V
+5V