Section 2a – INSTALLATION

Electrical Connections

Autopilot recommends that a licensed electrician or certified electrical contractor perform the electrical connections.
DANGER: ensure that the electrical panel or filter pump circuit breaker is turned OFF before wiring this unit.
Units are pre-wired from the factory for 230VAC. Short test leads are attached to the AC terminal strip and must be removed
prior to installation. You must provide the appropriate gauge wire for complete installations to the external timer, for One-
Speed Pump, or Two-Speed Pump connections.
Converting from 230 VAC to 115VAC: Remove the cover (see page 12) to access the circuit board. Rewire and attach the
included
jumper as shown below on the circuit board marked "TRANSFORMER PRIMARY".
*
*Jumper is provided with
your Installation Kit
Location of the
Input Jumper
Connections
Terminal Strip
AC LINE IN (Wiring diagram also located on inside of cover): select the diagram that matches your application.
For 230 VAC; Brown (Br) = Line 1, Blue (Bl) = Line 2, Green w/Yellow Tracer (Gr/Yel) = Earth Ground
For 115 VAC; Brown (Br) = Line, Blue (Bl) = Neutral, Green w/Yellow tracer (Gr/Yel) = Earth Ground
Terminal Strip
#1
#2 #3 #4 #5 #6
#1
#2 #3 #4 #5 #6
(LINE IN)
from Circuit Breaker
#1
#2 #3 #4 #5 #6
(LINE IN)
from Circuit Breaker
Control Box Connections
(Follow all state/local codes for electrical installations)
Power Circuit Board
Transformer
Pump Relay
INNER CONTROL PANEL
Time Clock,
Electronic
Connecting Pool Pilot to External Timer Setting:
Controller Relay
Connect Factory AC wires to the LOAD SIDE or the
or Circuit
Breaker
same location as the circulation pump wires (pump
connected to circuit breaker, time clock or electronic
(LOAD OUT)
controller).
to pump
Connecting Pool Pilot to One-Speed Pump
LINE-IN: Discard Factory ground (Green) wire. Cut Factory AC
wires to 5", strip and expose ½" of wire and connect from Terminal
#1 to #3, and terminal #2 to #4. Supply new LINE-IN wires from
Circuit breaker to Terminals #3 and #4. Ensure proper gauge wire is
(LOAD OUT)
used to power the pump.
to pump
LINE-OUT: Pump is connected to Terminals #5, #6 and Ground
lug.
Connecting Pool Pilot to Two-Speed Pump
Follow instructions for One-Speed Pump LINE-IN configuration.
Note: The pump is always powered. A safety shut off (wall switch)
between the circuit breaker and control box is recommended when the
circuit breaker cannot be accessed quickly
LINE-OUT:
Ground
1) Remove Factory #4 wire from Relay and Factory #6 wire from
Common
Low
High
Speed
Speed
2) Move #6 wire from Relay bottom row to the right top terminal
3) High Speed = Terminal
TAB 9
TAB 7
230VAC
TAB 5
TAB 3
TRANSFORMER PRIMARY
230 VAC
FACTORY SETTING
Terminal Strip. Cut wire in half, strip back jacket and expose
½" of wire, then jump to #6 Terminal strip.
and connect to the Low Speed of pump.
#5
5
TAB 10
TAB 9
115VAC
TAB 8
TAB 7
TAB 6
TAB 5
115VAC
TAB 4
TAB 3
TRANSFORMER PRIMARY
115 VAC
WIRING DIAGRAM
, Common = Terminal #6.
TAB 10
TAB 8
TAB 6
TAB 4