Autoplugin Key-V2 Manual do utilizador - Página 7
Procurar online ou descarregar pdf Manual do utilizador para Módulos GSM/GPRS Autoplugin Key-V2. Autoplugin Key-V2 8 páginas.
8.1. Default Settings 8.1.1 Apply factory settings
8.
Service
menu
* Factory setting
Recommended settings marked in Italics
1
–The module turns off the heater if battery voltage lowers to the adjusted limit
Troubleshooting
If a run-time error occurs during the heater operation, Autoplugin Key informs
about error code with LED flashing. The number of flashes in series corresponds to
the error code. See table 2 for errors description and possible solutions.
Error
Error
Code
Description
2
No answer
from the
heater
followed the
start
command
3
Battery low
4
Time limits
exceeded
5
Unsuccessful
start
7
Possible Reasons of
Error Appearance
Outer temperature
displayed in the CIP is
higher than +14 Celsius
degrees
Fuel level in the fuel
tank is close to empty
("Fuel Low" warning
indicator is illuminated
in the CIP)
The heater was blocked
after 3 unsuccessful
starts
The module has
determined that battery
voltage is below one
specified by settings
(items 3.1 and 3.2)
Time limit for
autonomous operation of
the heater is achieved
The heater was switched
off spontaneously at
startup
Solutions
The heater operates only at
temperatures below +15°C. It
is heater manufacturer
restriction
Refuel the car
Try to start the heater from
CIP's menu. If it doesn't start
up, make diagnostics of the
heater.
Charge the battery with special
charger (or start the engine to
charge) or cancel 3.1/3.2
module's settings
Run the engine or cancel 1.1
module's settings
Make diagnostics of the heater
if the error appears again
Table 2