Connection
Permanent connection to the car's wiring is required. See installation manual for
detailed connection schemes for various remotes.
RCP needs that timers and direct start / stop function for the heater control are
present in the CIP. Therefore it may be necessary to load the special software to
the CIP at first, by the means of Volvo dealer's equipment.
Troubleshooting
If a run-time error occurs during the heater operation, RCP informs about error
code with embedded LED flashing. The number of flashes in series corresponds to
the error code. See table 4 for errors description and possible solutions.
Error
Error
Code
Description
2
No answer
from the
heater
followed the
start
command
3
Battery low
4
Time limits
exceeded
10
Possible Reasons of
Error Appearance
Outer temperature
displayed by the CIP is
higher than +14 Celsius
degrees
Fuel level in the fuel
tank is close to empty
("Fuel Low" warning
indicator is illuminated
in the CIP)
The heater was blocked
after 3 unsuccessful
starts
The module has
determined that the
battery voltage is below
the specified by settings
items 3.1 or 3.2
Time limit for
autonomous operation of
the heater is achieved
(with applied setting 1.1)
Solutions
The heater operates only at
temperatures below +15°C. It
is heater manufacturer
restriction
Refuel the car
Try to start the heater in the
CIP menu. If it doesn't start
up, make diagnostics of the
heater.
Charge car's battery with
special charger (or start engine
to charge) or cancel 3.1/3.2
module's settings
Run the engine or cancel
applied setting
Table 4