1 INTRODUCTION
1.1 DESCRIPTION
This system is made up of a D-Box signal control box, QUASAR T25 A3 overspeed governor and ASG-UD
progressive safety gear, everything manufactured by Dynatech. This system operates as a complete system of
protection against car uncontrolled movements with the door open, also known as UCM.
This unit complies with the EN 81-20:2014 and EN 81-50:2014 standard by using the D-box as a signal management
system, the governor as a UCM detection component and the safety gears as braking components. The entire system
stops the car when a UCM occurs at a distance lower than 1 metre in accordance with the standard requirements.
This protection system is certified as detection and braking device in the scope of protection against car uncontrolled
movements with door open. Furthermore, each component making up the system has also been individually certified
for this purpose; obviously, without negatively affecting its certification as overspeed governor and progressive safety
gears when descending and braking component against overspeed when ascending.
UCM certification also includes the combinations between the different versions of these component models.
COMPONENT
D-BOX + QUASAR T25 A3+ ASG UD
QUASAR T25 A3
The assembly of this safety package in an installation exempts the installation itself from requiring the UCM certificate
but not from checking that the unit is in compliance with the standard's requirements. The installer must be held
responsible for fitting the system in the installation and checking its correct working order.
2 RISKS AND SECURITY WARNINGS
2.1 RISKS
Electrical hazard
Electrical hazard

2.2 SECURITY WARNINGS

Reference to the manuals for use and maintenance of the different components making up the unit is
recommended.
The D-Box + QUASAR T25 A3 + ASG UD unit is valid for installations where the P/Q ratio is above 0.7.
When a UCM occurs, a qualified technician is required for the installation to be operative again. Once the
problem causing the UCM has been solved, the reset button must be pressed in order to restore the safety
series and for the system to be operative again.
Note: This manual displays partial information on the instructions for use and maintenance of this product. Please refer to the customer
area in Dynatech's website in order to consult the full manual; http://customers.dynatech-elevation.com/
Cod: DYN62-3.02
D-BOX
ASG UD
Do not handle or open the box with its terminals connected to
the D-Box's electrical power supply.
Never handle the QUASAR + T25 overspeed governor's
interlocking coil.
CERTIFICATE
TRI/DAS.IV-A/000022-R3/17
CM/029-1/11
ATI/LV/007
ATI/PP/010
2