Gallagher T12 Nota de instalação - Página 4
Procurar online ou descarregar pdf Nota de instalação para Leitor de cartões Gallagher T12. Gallagher T12 11 páginas.
Também para Gallagher T12: Nota de instalação (13 páginas), Manual (12 páginas)
Installation Note | Gallagher T12 Reader
3.
Secure the base to the flush box using the two M3.5 screws provided. It is
important the base of the reader is flush with and tight against the mounting
surface.
If you are not mounting to a flush box, secure the base to the mounting surface
using the four fixing screws provided.
4.
Connect the reader tail extending from the facia assembly to the building cable.
Connect the wires shown below.
Note: Do not cut the 'Reserved' wires, they may be required later.
5.
Fit the facia assembly into the base by clipping the small lip, into the top of
the base and holding the top, press the bottom of the facia assembly down
into the base.
6.
Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver)
through the hole at the bottom of the base to secure the facia assembly.
Note: The recommended torque for the security screw is 0.7Nm (0.5 lb/ft). It
is important not to exceed the maximum torque of 1.5Nm (1.1 lb/ft).
4 | Part Number: 3E2512 R1
M3.5 screw
M3.5 screw
Positive
Negative
Reserved
Reserved
Reserved
CDXIV TX
CDXIV RX
Base
Building
cable
Red
Black
Orange
Green
Brown
White
Blue