ATTENTION: Anchoring only to solid constructions or buidings.
Basic rules for access ladders who can't be anchored:
P
Maximum height open air construction: 3x smallest base width (3x1.40=4.20m).
P
Maximum height construction in closed rooms 4x smallest base width (4x1.40= 5.60m).
P
When you need more height, widening the base of the access ladder to comply the basic rules.
CONSTRUCTION VARIANTS
A
when you need a access ladder who can lift up secure the standards with locking clips.
Afix advise customers to use standards with dismantable spigot. The special Fast FIX-fix-
ture prevent losing collars and adjustable base plates during lift up.
B
For a higher or lower exit level it is recommended to start with a platform stair 0.5, 1.0 or
1.5m height.
C
Combine platform stairs 0.5, 1.0 or 1.5m height with platform stairs 2.0m, height, makes it
possible to create a step out every 2.5 or 3.0m.