CopperOptics 150-1372-01 Manual - Página 10
Procurar online ou descarregar pdf Manual para Hardware de rede CopperOptics 150-1372-01. CopperOptics 150-1372-01 10 páginas. Line unit
Section 363-772-100
Revision 01
Term
MARGINS
Indicates the excess signal to noise ratio, at either the COT or RT, relative to a 10
Rate. mn is the current margin, cr is the minimum margin since last cleared, mx is the
maximum value since cleared, and N/A means Not Available. The normal range of a typical
margin is from 22 to 6 dB.
PULSE
Indicates the attenuation of the 2B1Q pulse from the distant end. PG-Flex operates with
ATTENUATION
pulse attenuations in excess of 30 dB. This value is related to the cable pair's 196-kHz loss.
The pulse attenuation is a more direct indication of the loop attenuation to the 2B1Q signal
than the 196-kHz loss. The normal range of pulse attenuation is from 1 to 32 dB
PPM
Indicates the relative offset of the crystal oscillator in the RT Line Unit from the COT Line
Unit's crystal oscillator. Any value between -64 and +64 is adequate. Values outside this
range indicate out of tolerance components or excessive temperature drift of critical
components.
HDSL 24 Hour
The number of 1-second intervals that contained at least one CRC error. This value is a
ES (Errored
running total of the last 24 hours.
Seconds)
HDSL 24 Hour
The number of seconds the HDSL loop was out of synchronization. This value is a running
UAS
total of the last 24 hours.
(Unavailable
Seconds)
Copyright © 1996, PairGain Technologies, Inc. PairGain is a registered trademark, CopperOptics and PG-Flex are
trademarks of PairGain Technologies, Inc.
Page 10
TABLE 4. GLOSSARY OF PG-FLEX TERMS
Definition
-7
Bit Error