ACTIVE EQUALIZATION:
11. Treble:
Boost and cut at 7kHz+14dB shelving type. Add or
remove edge and definition.
12. High Mid:
Boost and cut at 1 kHz +6dB -10dB, "Q Optimized,"
band pass type. Works on lower string harmonics,
and effects the punch of your sound.
13. Low Mid:
Boost and cut at 250Hz +6dB -10dB, "Q Opti-
mized," band pass type. Works on the main body of
your sound.
14. Bass:
Boost and cut at 60Hz +10dB, shelving type. Con-
trols low end push.
Outputs:
BI-AMP OUTPUT:
15. Boost:
A post EQ gain stage using G.I.V.E. technology
which adds "growl" as it is turned up.
16. Tweeter:
Master volume control for the tweeter (50W) amp.
Tweeter Hi-Cut:
Cuts frequencies above 10kHz, producing a more
"cone-like" (less metallic/harsh) sound from the
tweeter.
17.Woofer:
Master volume control for the woofer (Main) amp.
Woofer X-Over:
Press this button to engage the electronic crossover
for the woofer. This cuts frequencies above 5kHz
(Rolls off the highs).
POWER:
18. Power/Protect LED:
The LED flashes at turn-on for five seconds while
the amp powers up. The LED turns blue when the
amp is ready to play. Should the amp experience a
fault (over heat, over current) the amp will mute
and this LED will flash orange until the condition
is corrected. This LED turns green when the power
switch is turned off.
Standby Mode:
When using two or more 2001RBs in a master/slave
configuration, the power LED on the slave amps
will be orange. The LEDs will turn blue when the
master amp is turned on.
19. Power Switch:
Turns the amplifier on or off. Should a problem
occur during operation press this switch out first.
This turns the amp off, but does not completely dis-
connect the power from the AC mains. The power
LED should green at this point or flashing orange
if a fault is present.
14