Agrowtek SXG Manual de instruções - Página 3
Procurar online ou descarregar pdf Manual de instruções para Acessórios Agrowtek SXG. Agrowtek SXG 7 páginas. Co2 gas sensor
Installation Instructions
SXG sensors are designed for indoor wall mounting near ground level for monitoring carbon dioxide con-
centration limits. Consult your local authority for the quantity and location requirements for sensors and
alarm modules. Typical requirements are outlined below.
Installation Location Requirements:
• Intake fan to be no more than 12" from the floor.
• Locate the sensor on the wall furthest from the entry way.
• Locate the sensor near the center of the wall.
• Avoid areas with condensation or water spray.
• Always mount the RJ-45 connection on the bottom to avoid water ingress through the connection.
FLOOR
Installation Notes
NOTICE
GrowNET™ ports use standard RJ-45 connections but are NOT compatible the Ethernet network equipment.
Do not connect GrowNET™ ports to Ethernet ports or network switch gear.
DIELECTRIC GREASE
Dielectric grease is recommended on RJ-45 GrowNET™ connections when used in humid environments.
Place a small amount of grease onto the RJ-45 plug contacts before inserting into the GrowNET™ port.
Non-conductive grease is designed to prevent corrosion from moisture in electrical connectors.
• Loctite LB 8423
• Super Lube 91016 Silicone Dielectric Grease
3
SXG
GAS Sensor
aspirated
MADE IN
U.S.A.
• Dupont Molykote 4/5
© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
AGROWtEK
Technology to Help You Grow
CO
2
PPM
keep filter clean
TM
GrowNET
© Agrowtek Inc.
Link Port
www.agrowtek.com
Reset
MDOBUS RTU
• CRC 05105 Di-Electric Grease
• Other Silicone or Lithium based insulating grease
12" Max.