Product Installation Guidelines
TROUBLESHOOTING
PROBLEM
Taps are dripping water
Water is not flowing from tap
Spindle is difficult to turn
Handle is loose
© Galvin Engineering Pty Ltd
CAUSE
Ceramic discs are worn or damaged
Tap seat is damaged
Water is turned off
Ceramic discs are worn or damaged
Ceramic discs are worn or damaged
Screw has come loose
Version 1, 4 October 2022, Page 3 of 4
RECTIFICATION
Remove and inspect SBA. Remove
debris and/or replace SBA if
damaged.
Refurbish tap seat using a reseating
tool.
Turn on water
Remove and inspect SBA. Remove
debris and/or replace SBA if
damaged.
Remove and inspect SBA. Remove
debris and/or replace SBA if
damaged.
Tighten handle screw