Safe Use Locations
This device should only be operated in an above-ground, open-air situation where there is natural
ventilation, no stagnant areas, and where gas leakage and/or products of combustion will be promptly
diffused by wind.
Any enclosure in which you are using this device should comply with one of the following types of safe use
locations. Do not use this device in any area that does not comply with any of the following safe use locations.
• An enclosure with walls on all sides, but no roof/overhead covering.
• A partial enclosure that includes a roof/overhead covering but has no more than two (2) walls.
• A partial enclosure with a roof/overhead covering, more than two (2) walls, but meets one of the
following conditions:
• At least 25% of the total wall area is completely open and ventilated.
• At least 30% or more of the remaining wall side, back, and front areas are completely open and
unrestricted.
• If using on a balcony or patio, at least 20% or more of the total wall area must remain open and
restricted.
During operation, always make sure that all air inlets and exhaust vents are kept unobstructed and fully open.

Safety Features

High Temperature Sensor: The device will automatically disable the burner once the water temperature from
the dispenser reaches 125 °F (52 °C). It will automatically relight the burner once the water temperature
from the dispenser falls below 113 °F (45 °C).
Water Flow Sensor: Water must be flowing through the system in order for the burner to ignite. If the water
supply becomes restricted or ceases entirely (i.e. the Flow Switch is in the "off" position), the burner will
automatically be extinguished and will not relight until the water flow resumes.
Tilt Switch: If this device is moved during operation or is being operated on an unstable surface, the
appliance will shut down and must be switched off until placed in a suitable location.
Fuse Protection: Fuses are located in the cigarette lighter and pump power inlet. In the event of an issue
with the electrical supply, the fuse will blow and protect the electronic system of this device.

PACKAGE CONTENTS

• Portable water heater
• Carrying case
• Gas regulator
• Pump hose and plug
• Shower head attachment
• AC/DC adapter
• 12 V DC power adapter