Figure 3-4 Install Bracket
5. Loosen the four M6 screws on the PT joint bottom to adjust
the panning angle, and tighten the screws after the adjustment.
The panning angle is from -45° to 45°.
Figure 3-5 Adjust Panning Angle
Heat Resistant Bullet Camera · Quick Start Guide
6. Install the PT joint top to the mounting base of the camera
with four M6 screws.
Figure 3-6 Install PT Joint Top with Camera
7. Screw in the eight M6 screws, and adjust the tilting angle for
the camera. Tighten the screws after the adjustment. The
tilting range is from -45° to 45°.
Figure 3-7 Adjust Tilting Angle
3.3 Cooling and Dedusting Installation
Air or water cooling is required to cool the thermal camera
module if the device works in high-temperature environment.
3
The dedusting installation helps to remove dust from the device
window and cool the device, so that the image can be clearer.
Before you start:
Select a proper cooling method according to the working
environment of the device.
If the working temperature is between 50 °C and 100 °C
(including 100 °C), select air cooling method.
If the working temperature is between 100 °C and 200 °C
(including 200 °C), select water cooling method.
3.3.1 Air Cooling and Dedusting Installation
You can introduce compressed air to reduce the cavity
temperature of the device.
Steps:
1. Connect the compressed air outlet and ① (G1/2 air inlet) at
the bottom of the device with ② (G1/2 screwed pipe).
Figure 3-8 Pipe Connection for Air Cooling
Note:
The length of the screwed pipe in the package is 1 m, and you
can purchase the pipe according to the actual installation
requirement.