Corbin Russwin ASSA ABLOY Access M801, ASSA ABLOY Access M802 Instrução de programação - Página 9

Procurar online ou descarregar pdf Instrução de programação para Por fechaduras Corbin Russwin ASSA ABLOY Access M801, ASSA ABLOY Access M802. Corbin Russwin ASSA ABLOY Access M801, ASSA ABLOY Access M802 16 páginas.

Access 800
Series
Locks
Keypad Programming Instructions
M801, M803, M804, M806 Programming
5
To Enter the Emergency Code
99# Master Code*
50# 7# (User Location 03-2000)#
User Code (1-6 digits)*
User Code (1-6 digits)*
*
Enter a Lock Out User Code
99# Master Code or Supervisor Code*
50# 3# (User Location 03-2000)#
User Code*
User Code*
*
Note: The "lock out" user is location dependent and will lock out all users beyond this
location. To ensure that all users are locked out of the keypad, program this user at
User Location "04".
Enter A One Time User Code
99# Master Code or Supervisor Code*
50# 5# (User Location 03-2000)#
(1-6 Digits)*
(1-6 Digits)*
*
Enter An Extended Unlock User Code
99# Master Code*
50# 4# (User Location 03-2000)#
User Code (1-6 digits)*
User Code (1-6 digits)*
*
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
Copyright © 2018-2019 Corbin Russwin, Inc., an ASSA ABLOY Group
company. All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Yellow LED blinks
Yellow LED blinks
Yellow LED blinks quickly
Yellow LED blinks slowly
Yellow LED goes out
Yellow LED blinks
Yellow LED blinks
Yellow LED blinks quickly
Yellow LED blinks slowly
Yellow LED goes out
Yellow LED blinks
Yellow LED blinks
Yellow LED blinks quickly
Yellow LED blinks slowly
Yellow LED goes out
Yellow LED blinks
Yellow LED blinks
Yellow LED blinks quickly
Yellow LED blinks slowly
Yellow LED goes out
9
(617417440) FM359 7/19