DC8210 Parallel Arm Installation Instructions
A
Template
Mark Door and Jamb (for QUIK-INSTALL and adapter plate)
If top rail is 5-1/4 (133) or greater, use the template for the
If top rail is 1-3/4 (44) to 5-1/8 (130), use DROP PLATE (754F25) DIMENSIONS denoted by .
DOOR
FRAME STOP
FRAME STOP
TOP OF DOOR
1/2
(13)
3/8
(10)
1
(25)
QUIK-INSTALL BRACKET
754F18
To obtain extra closing force add 3 (77) to dimensions marked.
*
This will limit degree of door opening to 110°.
MOUNTING SCREW SPECIFICATIONS
ARM AND CLOSER BRACKET
#12-14 self-drilling screw
Type BSD. 1/8 (3) diameter
pilot hole required for Wood
Applications.
B
QUIK-INSTALL
Mount
Bracket
Countersunk
Countersunk
Holes (x4)
Holes (x4)
80-9380-8000-152 Rev. 09/06
A
B
C
This P a g e
2-3/4
(70)
1/4
(6)
PA ADAPTER
PLATE
3
4-3/4
3
(76)
(121)
(76)
10
(254)
}
{
Sex nuts, furnished
or
when ordered
#12-14 X 1-1/2 FH SELF-DRILLING (4)
#12-14 X 1-1/2 FH SELF-DRILLING (4)
OR
OR
1/4-20 X 3/4 FHMS W/ SEX NUTS (4)
1/4-20 X 3/4 FHMS W/ SEX NUTS (4)
D
E
F
G
Next Page ( 5 )
®
QUIK-INSTALL
*8-1/8
C L
(206)
5/8
(16)
1-1/2
5/8
(38)
(16)
C L
HINGE
OR
PIVOT
*3-1/8
(79)
3-1/16
(78)
*3-1/2
(89)
C
Mount Closer Body to
QUIK-INSTALL
Start the four mounting screws into the four closer mounting holes.
Place the closer onto the
mounting screws inserted into the four
Tighten the four mounting screws to fasten the closer body to the
QUIK-INSTALL
4
H
I
5
BRACKET provided.
SPACER BLOCK
FRAME
(When required)
ADAPTER
PLATE
NOTES:
Check hand of door, see page 1
Right Hand Application Shown. Left Hand
Opposite.
Dimensions given in inches (mm). Do Not
Scale Drawing.
Closer must be installed in a true horizontal
plane to ensure proper closer performance.
Door opening (up to 180°) is dependent
upon door, frame, wall and hinge/pivot
conditions permitting.
3/8
(10)
L
1/4-20 THREAD
Drill thru 9/32 (7) Enlarge to
3/8 (10) Dia. This Side Only
(4 Places)
Bracket
QUIK-INSTALL
bracket with the four
QUIK-INSTALL
bracket.
#12-24 x 5/8 FHMS (4)
#12-24 x 5/8 FHMS (4)
Parallel Arm
REF.
5/8
(16)
DOOR
1
SEX NUT
DOOR
LENGTH "L"
THICKNESS
1-3/8 (35)
1-9/32 (33)
1-3/4 (44)
1-21/32 (42)
& OVER
bracket slots.