Important Notes to the Installer
1. Read a llinstructions contained i nthese installation
instructions before installing t hecooktop.
2. Remove a llpacking material before connecting the
electrical supply t othecooktop.
3. Observe allgoverning c odes a ndordinances,
4. Besure to leave t hese instructions withtheconsumer.
Important Note to the Consumer
Keep these instructions withyourowner's g uide forfuture
reference.
IMPORTANT
SAFETY
INSTRU
S
Be sure your cooktop is installed
and grounded
properly
by a quaJified installer
or service
technician.
These cooktops
must be electrically
grounded
in
accordance
with
locat codes or, in their absence,
with the Nationa!
Electrical Code ANSI/NFPA No.
70--latest
edition
in the United States, or with
CSA Standard
C22.1, Canadian
Electrical
Code, Part
1, in Canada.
The eJectrical power
to the cooktop
must be shut off while
line connections
are being
made. Failure to do so coutd resutt in serious injury
or death.
Provide
Electrical
Connection
Install the junction box under the cabinet and run 120/
240 or 120/208 Volt, AC wire from the main circuit
panel. DO NOT connect the wire to the circuit panel at
this time.
Electrical
Requirements
Observe all governing
codes and local ordinances.
1.
A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on a
separate circuit fused on both sides of the line (time-
delay fuse or circuit breaker is recommended). DO
NOT fuse neutral. The fuse size must not exceed the
circuit rating of the appliance specified on the
nameplate.
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with the National Electrical Code ANSI/NFPA No. 70-
latest edition, or with CSA Standard C22.1, Canadian
Electrical Code, Part 1, and local (.odes and ordinances.
An extension
cord must not be used with this
appliance.
Such use may result in a fire, electrical
shock, or other
personal
injury.
2.
The appliance should be connected to the fused
disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed (:able. The flexible
armored cable extending from this appliance should
be connected directly to the grounded junction box.
The junction box should be located as shown in
Figure 2 with as much slack as possible remaining in
the cable between the box and the appliance, so it
(.an be moved if servicing is ever necessary.
3.
A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
_Unpacking
Instructions
(Models with Ceramic-Glass Smoothtop Only)
Model and Serial Plate
Figure
3
(Under Cooktop)
.
2.
Leave corner supports on cooktop until completion
of Electrical Connection.
Be sure the bottle of cleaner conditioner packed in
the literature bag is left where the user can find it
easily. It is important that the ceramic-glass
smoothtop be pretreated before use.
Electrical
Connection
Connect the flexible armored (:able that extends from
the surface unit to the junction box using a suitable
strain relief at the point the armored (:able enters the
junction box. Then make the electrical connection as
follows.
Electrical
ground
is required
on this