Adeunis RF ARF26 Manual do utilizador - Página 3
Procurar online ou descarregar pdf Manual do utilizador para Unidade de controlo Adeunis RF ARF26. Adeunis RF ARF26 13 páginas.
DIMENSIONS / PIN ASSIGNMENTS
N.B.:
- The signals SLE, SCK and SDATA correspond to the 3-wire serial interface for
programming the transceiver registers.
- The radio module is supplied by an external power source between VDC and GND. The
supply voltage should be chosen in the 3-5V range.
CHANNEL MANAGEMENT
• Principle
The transmitter and receiver have to be configured (frequency registers, control registers...) to
establish the radio link. This register configuration is performed by means of the SLE, SCK
and SDATA 3-wire serial bus.
The number of registers to be programmed depends on the operating mode: transmission,
receipt... Each word is programmed starting with the most significant bit (MSB) and each bit
is loaded on the rising front of SCK.
N.B:
- In transmission mode (Tx) and receipt mode (Rx), the programming is different for any one
channel.
- The transmitter and receiver have to work on the same channel to "understand" each other.
- For this programming, it is understood that low level corresponds to GND and high level to
VDC.
05-11-V3-psn
1 - GND RF
2 - ANTENNA
3 - VDC: 3 to 5V power supply
4 - GND: 0V ground
5 - DATAMSG: Data input/output
6 - SLE: Enable input
7 - SCK: Clock input
8 - SDATA: Programming data
input/output
9 - DATACLK: Received data
synchronisation clock