HIKOKI UC 18YFSL Manual de Instruções de Manuseamento
Before
charging
While
charging
Charging
Pilot lamp
complete
(red)
Overheat
standby
Charging
impossible
(2)
Regarding the temperature of the battery.
The temperatures for batteries are as shown in the Table 2, and batteries that have
become hot should be cooled for a while before being recharged.
Batteries
BSL1240M, BSL1225M
(3)
Regarding recharging time
Table 3 shows the recharging time required according to the type of battery.
Table 3 Recharging time (approx. min.) at 20°C
Battery
Voltage
BSL1225M
10.8 V
(3 cells)
NOTE
The recharging time may vary according to the ambient temperature.
In addition, the charge time becomes signifi cantly long in a low temperature environment,
but this is not abnormal.
4.
Disconnect the charger's power cord from the receptacle.
Table 1
Indications of the pilot lamp
Lights for 0.5 seconds. Does not
light for 0.5 seconds. (off for
Blinks
0.5 seconds)
Lights continuously
Lights
Lights for 0.5 seconds. Does not
light for 0.5 seconds. (off for
Blinks
0.5 seconds)
Lights for 1 second. Does not
light for 0.5 seconds. (off for
Blinks
0.5 seconds)
Lights for 0.1 second. Does not
light for 0.1 seconds. (off for
Flickers
0.1 seconds)
Table 2
Battery capacity (Ah)
Li-ion BATTERY
2.5 Ah
37 min.
Temperatures at which
the battery can be recharged
0°C — 50°C
BSL1240M
(3 cells)
11
English
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
Malfunction in the battery
or the charger.
4.0 Ah
60 min.