Adeunis RF ARF8047PA-B03 Manual de início rápido - Página 10
Procurar online ou descarregar pdf Manual de início rápido para Acessórios Adeunis RF ARF8047PA-B03. Adeunis RF ARF8047PA-B03 10 páginas. Sensors transceiver combined with a water-leak cable
Waterleak cable - Package IoT - Quick start guide 1.0.0
Waterleak cable - Guide utilisateur / User guide version V1.0.0
Waterleak cable - Guide utilisateur / User guide version V1.0.0
1.4. Using the product with default settings
The SENSORS has been configured to be in «Digital input». Once the SENSORS validates its start-up, it will send a 0x01 frame when water is
detected on the cable and also when the sensor has dried (to indicate "back to normal").
0
1
Code
Status
FR
0x01
Cf Status
Byte 2 : Indicate that the sensor has been configured in "Digital input"
Byte 3 : Indicate in which state the sensor is (OPEN (0) /CLOSED (1))
Byte 4 : Number of water detections since the last frame (from Open state to Closed state)
EN
Byte 5 : Number of "back to normal" detection since the last frame (from Closed state to Open state)
Bytes 6 to 10 : Not used
2
3
Sensor
State of the
type
digital input
4
5
PAYLOAD
Counter closed
Counter Open
state (water
state (back to
detected)
normal)
6
7
8
9
10
Not used
10 of 10